Stationary Compressor Series Models:
LU5-LU15E
LU15-LU30E
LU30-LU55E
LU55-LU90E
LU90-LU132
LU90-LU250
LU280S-355S
LU320-LU560
Oil-free centrifugal compressors:
LUT 125
LUT 200
LUT 300
Mobile Compressor Series Models:
Diesel driven
Electric motor drive
Diesel Engine Driven High Pressure Type
Inverter Type Compressor Series Models:
LU15-LU22 IVR
LU30-LU75 IVR
LU Series Screw Air Compressor
Full Performance Unit Series Models:
Fengshen LUD30-LUD90 LUD5- LUD30
After-treatment equipment series model:
LD series refrigerated compressed air dryer
LA series adsorption dryer
LF series high-efficiency filter
LG series high-efficiency degreaser
Baoding Youyi Mechanical and Electrical Equipment Co! Specializing in the sale of Atlas air compressor, now for Atlas air compressor Baoding area general dealer. Business items include air compressors, welding equipment, welding materials and auxiliary equipment, cutting equipment, motors, reducers, drilling and milling equipment, Kunlun industrial lubricants, fans and pumps, automatic welding equipment, lifting and transportation equipment and other mechanical and electrical equipment.
Atlas Air Compressor
Atlas was founded in 1873, is the world's first air compressor inventor, the company is headquartered in Stockholm, the capital of Sweden, there are more than 50 factories around the world, in more than 50 countries with sales companies in more than 85 countries and regions with agents, in 2006 the group's sales amounted to about 100 billion U.S. dollars.
The group consists of compressor technology division, industrial technology division, construction and mining technology division, of which the compressor technology division accounted for 50% of the group's total sales, headquartered in Antwerp, Belgium airpower is the world's largest compressor production base, known for its screw air compressor.
Atlas Copco is growing rapidly in the Chinese market. Copco is growing rapidly in China, where it employs more than 2,000 people and accounts for a significant share of the Group's sales revenue. More than half of this revenue comes from manufacturing, followed by process/construction and mining. Our company in China exports products to other sister companies in Asia and also to other overseas distribution centers.
Atlas Air Compressor Operating Procedures
I. Atlas Air Compressor[1] Before operation, the following should be noted:
1. Keep the lubricating oil in the oil pool within the range of the scale, and check that the amount of oil in the oil filler should not be less than the value of the scale line before the operation of the air compressor.
2, check whether the moving parts are flexible, whether the joint parts are tight, whether the lubrication system is normal, whether the motor and electrical control equipment is safe and reliable.
3, air compressor operation should be checked before the protective devices and safety accessories are intact.
4, check whether the exhaust pipe is smooth.
5, turn on the water supply, open the water inlet valve, so that the cooling water is unobstructed.
Second, the air compressor operation should pay attention to the first time after a long period of inactivity before starting, you must disk check, pay attention to any impact, stuck or ringing abnormalities and other phenomena.
Three, the machinery must be started in a no-load state, to be no-load operation is normal, and then gradually make the air compressor into the load operation.
Four, air compressor operation, normal operation, should always pay attention to a variety of instrumentation readings, and be adjusted at any time.
Fifth, the air compressor operation, should also check the following:
1, motor temperature is normal, whether the meter readings in the prescribed range.
2, whether the sound of the operation of the machine is normal.
3, the suction valve cover is hot, the valve sound is normal.
4, the air compressor various safety protection equipment is reliable.
Sixth, the air compressor operation 2 hours, the oil and water separator, intercooler, after the cooler oil and water discharge once, the oil and water in the air storage drum discharge once a shift.
Seven, air compressor operation found in the following situations, you should immediately stop, identify the causes, and be eliminated.
1, lubricating oil final break or cooling water final break.
2, water temperature suddenly rise or fall.
3, a sudden increase in exhaust pressure, safety valve failure.
4, the load suddenly exceeds the normal value.
5, abnormal mechanical noise.
6, motor or electrical equipment and other abnormalities.
Eight, the air compressor operation is completed, after stopping to close the cooling water inlet valve.
9, such as the power supply termination stop, the motor should be restored to the starting position, in order to prevent the restoration of power supply, due to the start of the controller does not act and cause accidents.
Ten, air compressor operation of the motor part of the operation must follow the relevant provisions of the motor.
Eleven, air compressor operation of the power part of the internal combustion engine shall comply with the relevant provisions of the implementation.
Twelve, air compressor operation parking more than 10 days, should be to the friction surface injection with sufficient lubricant. Parking for more than one month for long-term storage, in addition to the release of oil and water, remove all inlet and exhaust valves and blow clean, should also wipe the cylinder mirror, piston top surface, crankshaft surface and all non-coordinated surfaces, and oil sealing, oil sealing with a cover cover, in order to prevent moisture, dust immersion.
Thirteen, mobile air compressor in each towing before, should carefully check the walking device is intact, tight. The towing speed generally does not exceed 20 kilometers / hour.
Fourteenth, the air compressor operation, the set of storage cylinder and safety valves, pressure gauges and other safety accessories must comply with the Ministry of Railways on the compressed air storage cylinder safety technology requirements.
Fifteen, the air compressor air filter must be cleaned frequently, keep clear, in order to reduce unnecessary power loss.
Sixteen, air compressor operation sandblasting rust removal and other dusty work, should make the machinery and sandblasting site to maintain a certain distance, and should take appropriate dust measures.