Dual-energy knife (LC dual-energy knife, L-Leep, C- coagulation)
Edit the product function of this paragraph.
No smoke, no scab, no bleeding, no passage for virus invasion.
Edit the treatment scope of this paragraph.
Cervical erosion, cervical polyp, cervical cyst, cervical hypertrophy, condyloma acuminatum
Edit the technical features of this paragraph.
1, human body impedance detection technology, human body impedance detection technology, accurately control the therapeutic degree of RF diathermy. 2. Instantaneous voltage suppression technology can reduce the voltage to below 100V within 35ms, thus avoiding arc discharge. 3. Smokeless smoke system ①. Smokeless cutter: Absorb air in a short distance and in a large range, and collect the smoke before it spreads, so that the smoking rate reaches 97%. ② Large-diameter straight-through handle: large-diameter special operating handle to ensure unimpeded smoke and dust. ③ Anti-folding system of trachea: All pipes are equipped with anti-folding devices to prevent the pipes from being blocked due to unintentional bending, which will affect the purification effect. ④ Special vacuum system: 140L/MIN has super pumping function; 45dB ultra-low mute; It can generate an approximate vacuum pressure of -700mmHg, making it easier to collect smoke and dust. ⑤ Four-layer smoke and dust purification system a) Dust prevention: HEPA can filter particles with a diameter of 0.3 microns up to 99.99%. B) Deodorization: Activated carbon is specially used to adsorb dozens of harmful substances such as formaldehyde, benzene series, ammonia, oxygen and TVOC. Remove odor. C) Sterilization: Activated carbon can kill pathogenic bacteria such as Escherichia coli, Staphylococcus aureus, mold and pus, inhibit the spread of epidemic pathogens and completely eliminate pollution. D) Antivirus: Catalase can destroy the protein of solidified virus and decompose organic pollutants and some inorganic substances into carbon dioxide and water. 4. Patented surgical electrode ①. Conical electrode: it is convenient to cut and sample the cervical tissue, and it is convenient to suck the smoke and particles produced during the operation. ② Ring-shaped electrode: it is convenient for cutting off and sampling the cervical surface tissue and sucking the smoke and particles generated during the operation. (3) Square electrode: it is convenient to cut off and sample the larger cervical tissue, and suck the smoke and particles produced in the operation. ④ Cervical electrocoagulation knife: a kind of ablation electrocoagulation knife, which is used to taper the lesion after operation to ensure no bleeding after operation. ⑤ Cervical needle knife: The needle knife is convenient to pierce the tissue to form tiny holes, drain the liquid in the tissue, and effectively cure the disease.
Edit the product advantages of this paragraph
1, smokeless: the smoke collection and purification system ensures smokeless. (1) The smoke and dust collection system consists of a patented smokeless cutter head, a straight handle, an anti-folding gas pipe and a large-flow vacuum pump, which ensures that more than 97% of the smoke and dust are collected in the purification system before diffusion. ② Four-layer purification system can effectively remove particles, odor, bacteria and viruses. In the smoke and dust, carbon dioxide and water that are harmless to the environment are finally discharged. 2, no scab: RF biological diathermy technology and human impedance detection technology to ensure no scab. ① Radio-frequency biological diathermy technology has no trauma caused by traditional surgery, which activates squamous epithelial cells in the cervix and vagina, and basal cells and sub-basal cells in the basal layer of cervical epithelium begin to proliferate and differentiate into mature squamous cells. ② The depth and range of treatment are controlled by human impedance detection technology. After treatment, the damaged epithelium was covered by mature squamous epithelial cells without scar formation. 3, no bleeding: tissue self-heating coagulation can ensure no bleeding during treatment and after surgery. (1), during the treatment, the tissue coagulates by self-heat, which coagulates the epithelial tissue and vascular tissue within the treatment range without bleeding. ② After the operation, granulation tissue will not grow, and mature squamous cells will cover the wound without any injury and bleeding. 4. There is no defect of cervical epithelium ①. Coagulation necrosis: After radiofrequency treatment, the tissue turns gray or yellow-white solid due to dehydration and protein coagulation. Its characteristic is that the water content of necrotic tissue is reduced, while the structural outline is still preserved for a long time. ② Dissolution and absorption: The necrotic tissue itself and lysozyme of neutrophils decompose and liquefy the necrotic substances, which are then absorbed by lymphatic vessels or blood vessels, while the unabsorbable fragments are swallowed and digested by macrophages. ③ Regeneration of covered epithelium: After treatment, the coagulated tissue divides and proliferates from the basal layer cells at the edge or bottom of the wound and migrates to the defect center, first forming monolayer epithelium, then proliferating and differentiating into squamous epithelium, and no epithelial defect occurs.
Edit the product value of this paragraph.
1, care for patients ①, smokeless: avoid the harm of five harmful substances contained in smoke: toxic chemical components, substances that can induce mutation, active viruses, active cells and inactive particles. 2, no scabbing, no bleeding: to prevent infection, does not affect pregnancy. ③ There is no channel for virus invasion: there is no defect in cervical epithelium, and human papillomavirus cannot invade cells to cause infection. 4. No stress A) No psychological stress: no bleeding during treatment; After the treatment, I devoted myself to my work and life. B) No economic pressure: no scab bleeding after treatment and no repeated treatment. 2. Caring for the doctor 1, caring for the doctor's physical and mental health a) There is no smoke and harmful substances, which will not cause lifelong iatrogenic physical and mental harm to the doctor. B) There is no bad smell, which will not cause psychological harm to the doctor. (2) Relieve the psychological pressure of doctors. A) Minimally invasive treatment: five major diseases, special knives, special programs, and high minimally invasive treatment skills. B) There is no scab, which will not cause scab bleeding. 3. Build a doctor's technical authority a) Doctors provide leading minimally invasive cervical spine medical technology. 3. Necessary equipment to build a brand of minimally invasive cervical surgery. 1. Honorable name: LC dual-energy knife, L stands for Leep, and C stands for coagulation. ② Leading technology: four functions of impedance monitoring and RF diathermy, and symptomatic treatment with special tools. ③ Patients' cognition: no smoke, no scab, no bleeding, no virus invading the channel. (4) doctor's approval: establish the authority of minimally invasive cervical spine technology, avoid the harm of smoke and dust to yourself, and avoid the psychological pressure brought by doctors' repeated treatment. ⑤, one machine is multi-purpose: five major diseases, symptomatic treatment. ⑥ Create a green environment: avoid harmful smog and enhance the image of the hospital.
Dual-energy knife is a combined version of LEEP knife and self-coagulation knife. . . .