One, medical waste temporary storage point site issues
1, the specific requirements of the "Regulations on the Management of Medical Waste," Article XVII: Medical and health institutions should establish a temporary storage facilities for medical waste, equipment, shall not be stored in the open air of medical waste; temporary storage of medical waste time shall not exceed 2 days.
Temporary storage facilities and equipment for medical waste shall be located far away from medical areas, food processing areas and personnel activities, as well as living garbage storage places, and set up obvious warning signs and leakage prevention, rodent, mosquito and fly prevention, cockroach prevention, burglary prevention and prevention of child contact and other safety measures.
The temporary storage facilities and equipment for medical waste should be sterilized and cleaned regularly.
2, temporary storage points should be set up in the bottom of the floor.
Two, the temporary storage point of the basic facilities and equipment
Mainly 1, ultraviolet lamps; 2, if the wooden door or a large gap, the bottom should be nailed to at least 30 centimeters of the tin rodent-proof boards; 3, screens; 4, exhaust fans; 5, staff aprons gloves boots, etc., to prevent occupational exposure
Three, the temporary storage point of the internal requirements
1, internal System must be on the wall, a medical waste disposal system, the second is the internal management system of medical waste, the third is the relevant emergency plan, etc., this part of the content can be downloaded from the Internet, posted on the wall.
2, medical waste is strictly classified according to the requirements of the daily supervision and inspection has been exchanged, not to repeat. If in doubt, please consult or consult the hospital medical waste special (part-time) management personnel.
3, the temporary storage place according to the amount of medical waste generated by each unit to set up plastic buckets, and should be covered with airtight, not scattered anywhere, leakage.
4, improve the medical waste registration ledger. Individuals recommend at least two "medical waste register" for inspection, an entry record, including the hospital itself and the village health station to hand over, a record for the exit. Each hospital according to the situation, their own discretion.
Four, hospital wastewater treatment
In accordance with the requirements of the relevant provincial departments, hospitals must establish biogas digesters, hospital wastewater into the pool. And in the biogas digester outlet to set up a few square meters (hospitals according to the actual situation) of the pool, in the pool to add chlorine preparation for disinfection.