You are asking what to do if the servo error alarm of the wire bonding machine occurs? Readjust the encoder.
The servo error alarm of the wire welding machine is caused by the insufficient accuracy of the encoder. The encoder can be re-adjusted. The encoder can be adjusted by providing the rotor directional current that determines the phase sequence and direction to the motor winding to solve the problem. The servo error alarm problem of the wire bonding machine.
Wire bonding machines generally refer to ultrasonic wire bonding machines, which are distinguished by wire materials and can be divided into gold wire machines, aluminum wire machines and copper wire machines. According to the welding method, it can be divided into ball welding machine and wedge welding machine.