Hospital sewage management system?

1. Strictly implement the relevant provisions of the General Rules for Sterilization and Isolation Management.

2, keep the sewage discharge system smooth and unobstructed, regular maintenance of the hospital discharge system.

3, the staff to do their own protection, the collection of sewage wear gloves, wash their hands after the operation.

4, daily monitoring of total residual chlorine in the sewage 2 times, and make a good registration.

5, do a good job of sewage fecal coliform bacteria test every month, there are reports and ready for inspection.

6, every year to do a good job of pathogenic bacteria (salmonella, shigella) testing, not less than 2 times.

7, during the epidemic of infectious diseases, should increase the amount of sewage disinfectant put to ensure that the residual chlorine content of sewage treatment & gt; 6.5mg / L.

8, to maintain indoor air flow, environmental cleanliness.

9, sewage treatment raw materials properly stored, reasonable proportion.

10, a person to operate the sewage treatment device, sewage treatment personnel after training and licensed, and can correctly grasp the operation of the equipment and related health knowledge, responsible for the maintenance of the equipment, repair, in order to ensure its normal operation.

11, patient vomit, drainage fluid, surgical aspirate, laboratory fluid specimens and other contaminated liquids after disinfection and dumping into the toilet, into the hospital sewage treatment system.

12, sewage treatment equipment automatically timed regularly on the sewage put sodium hypochlorite for disinfection, sewage treatment personnel twice a day to measure the residual chlorine content, meet the standards before discharge, and keep records. Without disinfection or harmless treatment of sewage, sludge shall not be discharged, emptied or for agricultural fertilizer. The debris in the cesspool is regularly salvaged and incinerated.

13, treated sewage, sludge in line with GB8978-1996 "Comprehensive Emission Standards for Sewage" and GB18466-2005 "Pollutant Emission Standards for Healthcare Institutions", regularly accepted by the CDC and the County Environmental Protection Bureau of the monitoring of the hospital sensory department to carry out self-monitoring work.

14, the logistics section of the monthly sewage management system to check the implementation of the Hospital Sensory Branch from time to time spot checks, the results of the inspection and the month bonus linked to the implementation of rewards and penalties to cash.