I. Must have:
1. It can accommodate an independent reception room, treatment room, X-ray room, technician's room, sterilizing room and machine room.
2. There is a proper supply of water and electricity: the pressure of the water pipe should be no less than 2 kilograms when entering the dental chair; it should be ensured that all electrical appliances work with a voltage of 220 volts and a current of 50 hertz.
3. There are two or more telephone lines.
4. The downspout can be connected to a sewage disposal unit.
5. The interior height of the clinic structure is not less than 2.7 meters after renovation.
6. There are sound safety and fire fighting facilities.
2. Conditions that should be considered:
1. Possibility of outdoor advertising.
2. There is no clinic with similar services within 1000 meters
3. It is close to hospitals with better conditions.
4. Convenient transportation, high traffic flow, but the security situation is better.
5. Telephone lines can be connected to broadband Internet access.
6. There is a parking lot.
7. There is central air-conditioning.
8. It can accommodate restrooms.
Exterior Decoration Requirements for Dental Clinics
1. Have a conspicuous clinic logo (LOGO) and clinic name.
2. The color of the exterior is the same as the basic tone of the clinic's interior, unless the property management department has a hard and fast rule.
3. Glass door. The width is not less than 90 centimeters. The door can be labeled with the clinic logo, clinic name and opening hours, but no other text patterns.
4. The window in the same direction as the door of the clinic can be affixed with promotional materials on oral health care, but not with commercial colors, such as the manufacturer of the product and the price of the diagnosis and treatment items.
5. The glass of the other windows must not have any text on it.
6. Access to the clinic's main entrance is "barrier-free" for the disabled.
The general requirements for the interior of a dental clinic
1. The size of the clinic is roughly calculated by multiplying 35 square meters (or 40 square meters) by the number of dental chairs.
2. The color tone of the clinic is neutral, and it is best to choose the easier to change, i.e. light colors.
3. The clinic should be easy for patients to enter and exit, to take care of patients with limited mobility and the disabled.
4. The clinic is divided into reception, diagnosis and treatment and support of the three functional areas, each part should remain relatively independent, the patient should be as far as possible not to enter the support function area.
5. Convenient for the staff to walk, the clinic's pedestrian walkway width of not less than 150 centimeters, to avoid and reduce conflict with the patient's direction.
6. Ceiling and walls are smooth and flat, there can be no bumpy decorative patterns, paint with waterproof, mildew-resistant properties.
7. The intersection of the floor and the wall is in the shape of a garden arc.
8. In addition to the reception room and the doctor's office can be carpeted, the rest of the area can not be carpeted.
9. Adequate lighting, the use of white light sources, as far as possible, the use of diffused beam lighting, can not use chandeliers and wall sconces.
10. Audio equipment is available.
11. Fire fighting facilities (such as smoke alarm systems), the main corridor should have a fire evacuation route diagram.
12. There should be no steps inside the clinic, and there should be no threshold at the entrance of each room.
13. All rooms should be well insulated and ventilated, and when using central air conditioning, there must be air filters and return air outlets, and exhaust vents facing outside should not affect neighboring residences and units.
14. If possible, staff and patients should enter and exit the clinic through separate doors.
15. Doors and windows are well sealed, the width of the door of each room is not less than 75 centimeters, and the door panels should not have any decorative patterns or inlaid glass.
16. The corners of all furniture, door frames and window frames should be rounded instead of 90-degree angles to prevent bruises.
17. All wiring must be concealed and not exposed on the floor or walls.
18. Faucets should preferably use sensor switches.
19. All drawer handles should be simple, smooth and easy to clean.
20. The treatment room should preferably face south or east. Edit:
21. The design of the treatment room should give due consideration to taking care of the patient's privacy requirements.