Regulations of Tianjin Municipality on Thermal Energy Conservation Design of Public Buildings and Buildings?

In order to implement the national laws, regulations, principles and policies on energy conservation, improve the indoor environment of public buildings in Tianjin, improve energy utilization efficiency, reduce building energy consumption, and promote the application of new and renewable energy, the design standard for energy conservation of public buildings in Tianjin was revised according to the climate characteristics and specific conditions of Tianjin. Among them, what are the provisions of "Tianjin Public Building Energy Efficiency Design Standard" on buildings and building thermal engineering? The following is the content introduction of Tianjin public buildings and building thermal energy-saving design regulations brought by the construction network for reference.

general clause

The classification of energy-saving design of public buildings shall meet the following requirements:

1 According to the construction area, it is divided into Class A buildings and Class B buildings:

1) Buildings with a single building area of more than 300m2; Buildings with a single building area less than or equal to 300m2 but a total building area greater than 1000m2 are Grade A buildings;

2) Buildings with single building area less than or equal to 300m2 and total building area less than or equal to 1000m2 are Class B buildings.

2 Class A buildings are divided into educational buildings, office buildings, hotel buildings, commercial buildings, medical and health buildings and other buildings according to their functions:

1) educational buildings: nurseries, kindergartens, boarding schools, primary and secondary schools, institutions of higher learning, junior colleges, vocational and technical schools, special education schools, etc.

2) Office building: office building, commercial office building, scientific research building, archives building, administrative office building, hotel-style office building, judicial building, scientific experiment building, etc.

3) Hotel buildings: hotels, express hotels, hotels, hotels, guest houses, resorts, etc.

4) Commercial buildings: supermarkets, shopping centers, pedestrian streets, comprehensive commercial buildings, department stores, wholesale stores, farmers' markets, vegetable markets, joint-venture shopping malls, specialty stores, convenience stores, food courts, restaurants, fast food restaurants, banks, financial buildings, pawn shops, savings offices, etc.

5) Medical and health buildings: including general hospitals, specialized hospitals, emergency centers, ambulance stations, rehabilitation hospitals, community health service centers, sanatoriums, health centers, epidemic prevention stations, etc.

6) Other buildings: public buildings other than the above five building types.

The overall planning and general layout design of buildings should make full use of sunshine in winter and natural ventilation in summer. The main direction of the building should be south or near south. The overall planning should also consider reducing the heat island effect, and the related indexes of outdoor wind environment should be calculated and determined by simulation program.

Architectural design should follow the principle of passive energy-saving measures and make full use of natural lighting and natural ventilation.

Building modeling should be neat and compact, and the shape coefficient and building height should be controlled reasonably.

The fire protection structure, materials and products used in the building envelope should meet the requirements of passive energy-saving structural measures, and should meet the current relevant standards and regulations of the state and Tianjin.

The general plan design and layout of the building should reasonably determine the location of the energy room and shorten the distance of energy supply and transportation. The energy station and equipment room should be close to the load center.

This standard does not stipulate the building classification clause, and all Class A and B buildings shall be implemented.