What is the meaning of 16Mn(HIC)III in equipment papers?
The HIC steel plate with hydrogen sulfide corrosion resistance means that the steel plate needs hydrogen induced cracking (HIC) test. III is the level of control P S, which is divided into type I, type II and type III. It has good mechanical properties, weldability, high hydrogen-induced cracking resistance and sulfide stress corrosion cracking resistance.