Special equipment production unit on-site safety supervision and inspection items
Check whether the license is in force
Spot check special equipment management personnel, inspectors, engineers and technicians, operators have the appropriate qualifications
Spot check the design and manufacture, installation, major maintenance files are established
Spot check design drawings approval procedures meet the requirements
Product production process information is kept complete, whether the factory is accompanied by quality certification and other relevant documents. >Spot check whether the approval procedures for design drawings meet the requirements
Spot check whether the product production process information is preserved intact, whether the special equipment factory is accompanied by quality certification and other relevant documents and information, special equipment installation, renovation, maintenance, whether the completion of the transfer of the relevant technical information documents
Spot check the type test, supervisory and inspection information to meet the requirements
Recent A review of the corrective action items put forward to confirm whether or not in place
Spot-check whether there is beyond the scope of the license and license validity of the manufacture of the situation
Check the production unit of the legal representative, the name, property rights, production sites, etc., changes to the licensing department in a timely manner to declare the
Special equipment using the unit of the on-site safety supervision and inspection program
Using the unit of safety Management inspection program
Institutions and systems:
Whether to set up a safety management organization or full-time and part-time management personnel
Whether to establish a safety management system and job safety responsibility system in accordance with the provisions of the
Whether to develop emergency response to accidents, rescue plans and records of drills
Equipment file:
Whether to establish equipment File, whether complete, whether good storage
Sampling of equipment in the periodic inspection period
Sampling of equipment in accordance with the provisions of routine maintenance or overhaul and records
Personnel files:
Sampling of safety management personnel and operators whether the validity of the documents
Whether the special equipment operating Personnel training records
Boiler use check items
Operators: on duty operators have valid certificates
Use of registration and inspection marks: whether there is a use of the registration certificate, whether in the validity of the inspection period
Safety attachments and safety protection devices: liquid level (surface) gauge whether the highest and lowest safety level marking
Safety valves have a valid calibration
Safety valves have a valid calibration marking
Safety valves have a valid calibration marking
Safety valves are not used in the boiler. Safety valves have a valid calibration report or mark
Pressure gauge has a valid calibration certificate or mark
Operation: water level, pressure is within the allowable range
Whether to fill out the operating records in a timely manner
Water (media) quality treatment: whether there is a water (media) quality testing records, the frequency of testing in line with the provisions
Pressure vessels The use of inspection items
Operators: on duty operators have a valid license
Use of registration and inspection marks: whether there is a use of registration cards, whether in the inspection period
Safety attachments and protective devices: safety valves have a valid calibration report or mark
Pressure gauges have a valid valid certification or mark
Pressure vessels have a valid inspection certificate or mark
Annual inspections: water (medium) quality treatment: water (medium) quality testing records, testing frequency is in line with the provisions of
Pressure vessels p>Annual inspection: whether the annual inspection in accordance with the provisions of the annual inspection (check the annual inspection report of the equipment)
Pressure piping use inspection program
Operators: on-duty operators have a valid certificate in accordance with the provisions of the
Use of the registration and inspection marks: whether there is a use of the registration card, whether the inspection is valid
Safety accessories and protective devices: whether the safety valve has a valid calibration report or mark
Pressure gauge has a valid certification or mark
Safety accessories and Protective devices: whether the safety valve has a valid calibration report or mark
Pressure gauge has a valid calibration certificate or mark
Operation: whether the operation, maintenance and daily inspection records
Annual Inspection: whether to carry out annual inspections
Elevator use of the inspection program
Operators: whether the site operators have a valid certificate
Operators: whether the site operators with Valid documents
Use of registration and warning signs: whether the use of registration signs, and in accordance with the provisions of the elevator is fixed in a conspicuous position, whether the next inspection period
Safety precautions and warning signs are placed in a conspicuous position easy to the attention of the passengers
Safety devices: the elevator set up in the alarm device is reliable, whether the connection is smooth
Spot check whether the function of call floor, floor and other display signal system is effective, and whether the indication is correct (any one of them, a floor)
Whether the door anti-pinch protection device is effective
Whether the emergency stop switch is effective at the entrance of the escalator and the moving walkway
Whether the calibration report of the speed limiter is in the validity period
Maintenance: Whether there is valid maintenance contract
Whether there is valid maintenance contract
Whether there is valid maintenance contract
Whether there is valid maintenance contract
Whether there is a maintenance record, maintenance cycle is in line with the provisions of the
Crane use of inspection items
Operators: on-site drivers and commanders have valid certificates
Use of registration and warning signs: whether there is a use of the registration card, whether there is a safety inspection and certification mark and according to the provisions of the fixed in a conspicuous position, whether the test period of validity
Whether there are necessary precautions for the use of warning signs
Safety devices: operation warning bell, emergency brake is effective
Maintenance status: spot check whether the maintenance records are filled out in a timely manner.