What are the matters of medical airtight door safety use

Summary: medical airtight door other names are: operating room automatic door, medical sensor automatic door, radiation automatic door, radiation automatic door, operating room airtight door, etc., the above medical airtight door are applicable to the following medical airtight door safety matters as well as medical airtight door maintenance. Specific medical airtight door safe use of what matters as well as medical airtight door maintenance need to pay attention to what, let's take a closer look at the text! First, the safe use of medical airtight door matters

1, please in order through the medical airtight door, please do not close the door or door closed when forced through the medical airtight door, to ensure that the door is open to allow more than one person's space through the medical airtight door.

2, do not block the medical airtight door, punch the medical airtight door, or use external forces to damage the medical airtight door equipment and the door.

3. Children under 1.2 meters tall, the elderly and the disabled should pass through the medical airtight door with the help of their guardians, otherwise they will be responsible for the consequences.

4. Please do not stay for a long time in the doorway of the medical airtight door, and do not put any obstacles in the doorway of the medical airtight door.

5, medical airtight door in the automatic sensor state, please do not stay in the sensor area for a long time.

6, in the power outage can be manually pushed to both sides of the medical airtight door door fan, medical airtight door failure or emergency, please close the medical airtight door, manually push open the door.

Second, the medical airtight door maintenance need to pay attention to what

Medical airtight door manufacturers not only in the production of a full range of major hospitals to solve the problem, but also in the maintenance of maintenance in the latter part of the maintenance of certain insights, the following for you to explain the maintenance of hospitals and medical airtight door precautions:

1, open the door of the medical airtight door, the operator must stand in the direction of the door machine running status to see the operator to see the door. Door running condition of the orientation of the operation, or easy to accidentally damage.

2, medical airtight door and door machine must not touch with acid, alkaline solution to prevent corrosion of medical airtight door appearance.

3, at least 3 times a year to regularly check the medical airtight door in the operation, glide and other parts of the normal state, and according to the needs of timely refueling, in order to the normal use of medical airtight door.

4, medical airtight door in the opening, the strength should be moderate, try to keep the opening and closing speed uniform.

5, medical airtight door in the use of the process type, found that there is easy to stop the operation of the door should be timely.

6, operating room airtight door in the process of opening the operation found to have a large tremor or easy sound should be stopped to see if there is easy to block, such as the need to clean up before use.