Haier biological safety cabinet let you enjoy the fun of work
Functional features
Operation of the ease of mind
All the abnormal state of all the alarms are set up to indicate that the misuse of the set of interlocking protection, even if the untrained, will not cause harm.
This design has been recognized as the international leading level, and was awarded a national patent (Patent No.: ZL 2005 2 0125227.5)
Use of peace of mind
Operating state of the full display, at a glance to know the fans, filters, ultraviolet lamps, airflow and other operating indicators.
Perfect structure
Ergonomic 10 ° tilt angle design, better operating experience;
Working area of stainless steel integration of the three sides of the wall plate structure, 12mm arc transition to avoid cleaning dead ends;
Cabinet and bracket can be separated, a variety of bracket options;
Equipped with the international popular handhold bracket to make the operator safer and more comfortable;
Operator more secure and comfortable. The operator is safer and more comfortable;
Equipped with safety splash-proof sockets and water and gas faucets. Reliable protection Patented technology of front window glass balancer suspension system design, eliminating laboratory leakage due to misuse;
6mm thickness of UV tempered glass front window, providing safe and effective protection;
Innovative airflow isolation technology, eliminating leakage along the upper edge of the front window and on both sides of the window (Patent No.: ZL 2005 2 0125549.X);
Full leakage protection design, even without a grounding wire can be used at ease;
Strict air tightness test, pressurized 500Pa, keep the air pressure not less than 450Pa after 30min.
Safety alarm design
Door limit alarm - open the door to exceed the height of the safety height Alarm to prevent leakage of experimental microorganisms;
Airflow fluctuation alarm - airflow fluctuation of more than 20% alarm to ensure that the air curtain is reliable;
Shutdown fan door is not closed tightly alarm - to prevent the leakage of experimental microorganisms;
Filter breakage alarm - to prevent pollution caused by the laboratory;
Filter life is less than 20% suggestive alarm - to prompt the preparation of replacement in advance, so as to avoid delays in the work.
Excellent performance
Passed the potassium iodide method personnel protection test, the protection factor of the front window operation port ≥7×105
Product protection test: the total number of bacterial colonies ≤1CFU/times
Cross-contamination protection test: the total number of bacterial colonies ≤1CFU/times Linkage self-locking function
Only in the fluorescent lamp, the blower and the glass front window all Only when the fluorescent lamp, fan and front window are all closed, the UV lamp can be turned on - to prevent accidental contact with UV rays;
Lift up the front window, the UV lamp will be turned off automatically, the fluorescent lamp will be turned on automatically, and the fan will start to run automatically - to prevent the leakage of microbial organisms;
When the door is super high, the UV lamp and fluorescent lamp will be turned on automatically. When the door is too high, the UV lamp and fluorescent lamp can not work - to prevent the operator from working in an unsafe state;
After closing the front window glass, the fan automatically stops - to prevent the fan from running in the air. (Linkage self-locking function has protective compensation design for all misoperation,
Patent No.: ZL 2005 2 0125227.5)