Connect the over-planting number saw in F5 of the inverter.
Restore the switch in the elevator car to the normal state, and carry out the machine room maintenance operation (MODE 3 SET) on the elevator with the keypad on the main control board in the machine room, so that the elevator will run to the lowest floor at a low speed, and the car will be at the lowest floor level position.
The keypad on the main control board is used to measure the floor height (MODE 2 SET). The elevator will start from the lowest floor at low speed and run upward for floor height determination.
The elevator reaches the level of the highest floor, hits the limit switch to stop but does not open the door, uses the keypad on the main control board to restore the elevator to the normal operation mode (MODE 0 SET), exits from the floor height determination mode, the floor height determination is completed, and returns to the base station without call after 30 seconds.
Note that the elevator should not change the running state of the elevator when the floor height measurement is in progress, otherwise it will destroy the running state of the elevator's floor height measurement and terminate the floor height measurement.
When using the keypad on the main control board, you should be very careful to avoid entering the floor height measurement mode (MODE 2 SET) by mistake, which may result in the loss of floor height data.
After the layer height determination is completed, check the data of the inverter with the special keyboard of the inverter, the correct number of magnetic separator boards should be written in F4.00 address, and the corresponding number of layer height pulses should be written in F4.09~F4.41 (1~32 layers).
The hall door of HGP should be 1-16 floors: 1 and 2 of XI1 plug-in, 1 and 2 of XI3 plug-in of 17-32 floors, and the flat cable is orange, and the coupe door should be: 9 of Y2 and 20 of Y3.