One, the isolation of the hotel should have the hardware conditions

Two, the isolation of the hotel operation management and emergency operation guide

Three, after the epidemic recommended as the isolation of the use of the hotel after the epidemic is over, the following recommendations can be provided

One, the isolation of the hotel should have the hardware conditions

The hotel as a temporary quarantine area should have the following aspects of the basic Hardware conditions

(1) rooms: there should be a certain number of rooms, can solve part of the number of people need to isolate the requirements. Each room should have an independent bathroom, to avoid the use of public **** bathroom recommended number of rooms in 50 ~ 200 appropriate, the number of rooms is too small to meet the number of isolation of personnel requirements, and easy to cause the waste of medical service personnel; the number of rooms is too much to increase the number of emergencies emergency response to the difficulty of dealing with the situation, and the hotel's operating costs are too high. No open windows or windows can be opened ventilation area of less than 0.2 square meters of the guest room is not recommended.

(2) The hotel can be divided into two areas: isolation area (contaminated area/semi-contaminated area), as well as the medical work area and life service logistics area (clean area). (For terminology, see "new coronavirus infected pneumonia infectious disease emergency medical facility design standards" T/CECS661-2020)

(3) air conditioning and ventilation system: priority should be given to the use of split air-conditioning or frequency conversion refrigerant multi-connected air-conditioning hotel. Each room should have an independent fresh air supply (exhaust) and filtration system to prevent the spread of viruses. If the guest rooms are centralized return air treatment and air conditioning system without fresh air, all air-conditioning units should be turned off, closed all the guest rooms of the air outlet and return air outlet, set up mechanical ventilation devices or have openable windows. Equipment control should be operated by the hotel operation and management personnel responsible for.

(4) water supply and drainage system: the hotel should have perfect water supply, hot water, drainage and fire fighting facilities. Living water quality should be in line with the current national standards, "drinking water quality health standards" GB5749 provisions, living hot water heating equipment outlet temperature should not be less than 60 ℃. Isolation of confirmed cases (nucleic acid virus test positive or CT chest radiographs) but did not show obvious symptoms of discomfort of the patient's hotel room water supply and sewage, wastewater drainage system and other non-room functions of the water supply and drainage system should be set up separately; outdoor should be equipped with the setting of sewage treatment facilities.