Siemens s2000 fault repair

Siemens S2000 color ultrasound diagnostic system black screen can not start fault technical repair Yum color ultrasound MyLab0/70/90 repair color ultrasound power supply repair color ultrasound monitor repair

1: Measurement key can not be measured.

2: the machine soft shutdown when the number of bars scrolling back and forth can not tube machine.

3: a key is damaged, the trackball can not be used.

4: Black screen error 07 and a series of other problems.

MyLab?15 MyLab?20 (Charm 15/20) Esaote Ultrasound Introduction Sales as well as Repair

Siemens S2000 Ultrasound Diagnostic System Black Screen Cannot Start Failure Technical Repair Esaote Ultrasound Repair Esaote Ultrasound Sales Esaote Ultrasound Parts Esaote Ultrasound Power Supply Repair Esaote Ultrasound Display Repair Esaote Ultrasound Probe Repair Esaote Ultrasound Circuit Board Repair <

The ab?15/20 is Esaote's compact control panel ultrasound system.

MyLab?15 and MyLab?15 CW are two high-performance color Doppler ultrasound machines that can be downsized to black and white ultrasound.

MyLab?20 and MyLab?20 PLUS are highly sensitive color Doppler platforms.

With real-time triple synchronization and real-time dual amplitude. This modern powerful diagnostic tool and high-performance, high-quality 2D image transducer can meet the needs of diverse medical fields.

Siemens S2000 color ultrasound diagnostic system black screen can not start faulty technical repair MyLab?15/20 can be equipped with convex array, line array and intracavitary probes, including Esaote unique 200 ° large fan angle wide angle of view probe.

Support USB interface, support embedded USB excuse convenient and fast image storage. Images can be dynamically stored and played back in real time, or output in different formats via USB or printer.

Byson Esaote

Siemens S2000 color ultrasound diagnostic system black screen can not start faulty technical repair Esaote is in Italy, to the limb joint MRI and ultrasound products and. Their products are expensive and do not sell well. Their product My Lab series is updated very fast. Influenced by TOSHIBA, their sales strategy started to become very aggressive. They started to invest heavily in many regions to build up the market. myLab 20, myLab 25, myLab 30, myLab 40 (2007), myLab 50 (2005), myLab 60, myLab 70, myLab 90. some of the products with similar numbers have the same movement and the probes can be used universally. myLabClass Tabletop Color Ultrasound.

Portable ultrasound MyLabFive, MyLab 25Gold, MyLab30. MyLab30Gold Ophthalmic ultrasound.

Handheld black-and-white ultrasound MyLabGuide

Portable touchscreen ultrasound MyLabOne

MyLabTwice (2010) is its current main product, which claims to be a dual-platform. Ultrasound images can be transmitted wirelessly. wifi to the portable display ultrasound MyLabSat next to it. myLabSat can be hand-carried to other locations for consultation.

CnTI Ultrasound Imaging Technology. Has been pursuing high-frequency line array. Current width radiation 3-22MHz UHF. Has MyLabVinco technology (2010)

Siemens S2000 color ultrasound diagnostic system black screen can not start faulty technology repair Esaote is also actively operating overseas mergers and acquisitions, the acquisition of the French Kontron Kontron Ultrasound Siemens X300 can be used normally after booting, within an hour there will be a dialog box to report an error notify the manufacturer to repair and then automatically shut down, every day will irregularly The appearance of a few times a day. This kind of failure is Siemens B ultrasound common problem, X150 X300 G40 prima and so on will appear the same situation.

This situation is analyzed first

1, enter the maintenance mode, press the menu key, the password is empty, self-test once to see if there is any obvious error message.

2, and then into the EVENT LOG, plug in the U disk hold down CTRL + ALT + S to download the error log, analyze the internal TXT file, there will be a detailed description of the reasons for the error, which can be used as a basis for reference, the common is HV error or TI error

3, the first suspected HV problem, high voltage is supplied by the DCDC board, in the left side of the machine Shu Qi The board is the DCDC board, 48V input, HV is 100V, with a meter to measure the dynamics of 100V, when the machine appears after the error 100V has been there

4, if the 100V stops, it means that the DCDC must have a problem, if the 100V has been there, then the possibility of the TI board is very large

5, when the error does not appear, the ultrasound When the error does not appear, the ultrasound area appears water ripples of lateral interference DC board is more problematic

6, when the error does not appear, the ultrasound probe is very loud DC board is more problematic

7, test the machine there is another way to let the machine to enter the maintenance interface, go into the maintenance interface, do not exit the machine to run all the time. If there is a problem with the machine, generally does not appear dialog box, the machine will not shut down, when the internal problems, exit the maintenance interface, the ultrasonic area has no echo, this time you can use the table to measure the parameters of the various points, and the normal state of the machine for comparison.

8, DC board repair, you can carry out offline repair, connected to the 48V power supply, the amount of parameters in various places is normal

9, TI board offline repair, TI board caused by the causes of the failure of quite a lot of 5,6 places will have the possibility of the BGA problem, then some trouble, this involves technical issues I do not elaborate on the call to consult the maintenance of technology

9, TI board offline repair, TI board caused by the failure of quite a lot of reasons, 5,6 places will have the possibility of BGA problem, some trouble, this involves technical issues I do not elaborate on the call to consult the maintenance technology

10,3 probes are radial interference, as if in the image of a layer of static interference, interference layer with the image is separate, gain adjustment does not affect the image changes. Most of this fault is TI board contact is not good, reinstallation may be good.