The food factory is disinfected with 84 disinfectant. Is there any way to counteract this smell?

Disinfection with ozone can avoid the smell of disinfectant; The traditional large-scale disinfection method is fumigation with formaldehyde. As mentioned above, formaldehyde fumigation has many disadvantages, but ozone disinfection is a good method. The method is to put the ozone generator directly in the air duct of the air conditioning system, which is called the built-in generator. With the airflow in the air duct, ozone is sent to various clean areas for disinfection and sterilization, and the remaining ozone is sucked into the air return port and taken away by the central air conditioner. You can also put the ozone generator outside the air outlet of the central air conditioner, pump ozone into the air duct of the central air conditioner, and then send it to each clean room. This is called an external ozone generator. The external ozone generator is easy to install and maintain, but the manufacturing cost is high. The disinfection effect of the two methods is the same. According to the requirements of the disinfection standard of the Ministry of Health, the ozone concentration of air disinfection is 5ppm, but in fact, the disinfection of clean areas is not only the disinfection of air, but also the disinfection of the surface of objects, so the designed concentration is 10ppm. HW-YD series products can meet the requirements of external sterilization of air conditioners, direct sterilization in workshops and simultaneous sterilization in multiple workshops. The machine also has shockproof wheels; You can push it by hand and move it! Deeply loved by thousands of enterprises! Turn it on for two hours before going to work and turn it off after work every day, which can ensure that the planktonic bacteria and dust-reducing bacteria in the clean area meet GMP requirements within one day, and the100000 aseptic requirement only needs to be turned on for half an hour!

The test report showed that the ozone concentration in each clean area reached more than 10ppm within 40 minutes by using the ozone generator, and all the bacteria tests were qualified. And qualified every day, completely replacing the troublesome formaldehyde fumigation and disinfection. At the same time, non-productive work and energy consumption are reduced, and satisfactory results are achieved. ?

Disinfection and sterilization of space: clean rooms outside the central air conditioning purification system or other rooms that need sterilization need to be sterilized separately. The method is to choose an ozone generator and install it directly in the room. Set the disinfection time according to the need, and automatically shut down after disinfection, which is very convenient to use. ?

Disinfection and sterilization of the surface of articles: raw materials, tools, packaging materials, etc. during the production of cosmetics. Are often disinfected, as well as disinfection cabinets, transmission windows and so on. Often used. The traditional method is disinfection with ultraviolet rays. The main problem is incomplete disinfection, and it can be used in places with low requirements such as transfer windows. But it is far less effective than ozone. Disinfection cabinets made of ozone generators are very popular in food factories. Everything that is not afraid of ozone corrosion can be put in the cupboard for disinfection. Ozone concentration can be designed to be higher. ?

Disinfection and sterilization of water: There are many places where cosmetics factories use water. According to different water quality requirements and different technological processes, the general ozone water treatment methods can achieve satisfactory results. ?

Ozone function: sterilization, disinfection, deodorization and purification; Dual-purpose (that is, can be used for space disinfection? -? It can also be used for water treatment and disinfection.

Scope of application: family, school, hospital, warehouse, hotel, kindergarten, office, farm, food factory, cosmetics, edible fungi, car beauty, etc. Dressing room, packaging workshop, drinking water, purified water, mineral water, food processing and production water, swimming pool water purification, sewage treatment? ……?

Many times; We can't detect the ozone concentration; Few manufacturers buy ozone concentration detectors because they buy ozone sterilizers; Then how do we test whether the sterilization is up to standard and meets the national requirements?

It is the simplest and most effective method to detect settling bacteria; Sampling settling bacteria before ozone sterilization? Then turn on ozone sterilization for half an hour? Wait for ozone decomposition for half an hour before testing settling bacteria? The ozone generator designed by ordinary manufacturers for workshop disinfection only needs to disinfect the space for half an hour to one hour, which can meet the national 100,000-level aseptic requirements.

Guangzhou Huanwei Environmental Protection Technology Co., Ltd. is a professional manufacturer of ozone equipment; The quality is guaranteed; The service life is more than ten years;