In order to implement the Shenyang Municipal Environmental Protection Bureau, "on the development of heavy metals and hazardous chemical enterprises "self-examination and self-correction" environmental hazards special action notice", to prevent the occurrence of environmental pollution incidents of hazardous chemicals. The occurrence of environmental pollution of chemicals, my company (Shenyang Chemical Co., Ltd.) at the end of March, the beginning of April to carry out environmental hazards of self-checking and self-correction activities, the report is as follows.
1. Self-inspection of environmental protection procedures
My company was founded in February 2007, and the company's environmental protection procedures are as follows.
In March 2007, submitted to the "Shenyang Chemical Co., Ltd. coatings and auxiliary materials construction project Environmental Impact Report," in July 2007, the EIA through the approval.
"Three simultaneous" acceptance application report has been submitted to the Development Zone Environmental Protection Bureau, is waiting for acceptance monitoring.
2. Self-inspection of pollution control facilities
In accordance with the requirements of the EIA, water, gas, sound and slag pollution control facilities have been established.
(1) Prevention and control of air pollution
The production workshop should be installed with air collector, induced draft fan and exhaust pipe, and the production should be closed, so as to realize all the organized emission of organic solvents.
(2) Water pollution prevention and control
Living sewage is discharged into the drainage network of the plant through the septic tank after treatment, and then into the sewage treatment plant of the chemical industrial area by the municipal drainage network; the sewage water of the indirect cooling circulating water is clean sewage, and it is directly entered into the sewage treatment plant of the chemical industrial area by the municipal drainage network; the floor of the washing workshop, the drainage water of the laboratory, and the drainage water of the washing tanks are treated by the regulating pool, the slanting plate sedimentation, Activated carbon adsorption treatment by the municipal drainage network into the chemical industrial zone sewage treatment plant.
(3) Solid Waste Pollution Prevention and Control
Life garbage is handed over to the sanitation department for harmless treatment.
Has formulated "Shenyang a chemical company limited solid waste environmental management manual", and reported to the Development Zone Environmental Protection Bureau for the record.
(4) Equipment noise prevention and control
Enterprises will be fans, pumps and other noise-producing equipment installed in the workshop, after the plant sound insulation, distance attenuation, the noise at the plant boundary can meet the requirements of Class III standards in the "industrial enterprise factory noise standards" (GB12348-90).
4. Self-inspection of pollutant discharge
According to the EIA report, it is confirmed that the total drainage water of our company meets the requirements of the influent water quality of the sewage treatment plant.
The waste solvents used for cleaning are recycled for the preparation of dark-colored paint and are not discharged. The tested samples and waste reagents are recycled and not discharged.
Our company does not have the ability to self-testing, commissioned qualified units to regularly monitor to ensure that the pollutants meet the emission standards.
5. Self-inspection of hazardous waste management
In accordance with the "Shenyang a chemical company limited by solid waste environmental management manual", strictly in accordance with the "People's Republic of China *** and the State Law on Prevention and Control of Environmental Pollution by Solid Wastes" requirements for management.
According to the "National Hazardous Waste List" and the EIA, the paint residue, distillation tower kettle residue, waste activated carbon, waste filters, waste rags are managed according to hazardous waste. According to the relevant provisions of the national "Hazardous Waste Storage Pollution Control Standards" (GB18597-2001), hazardous wastes are stored in the plant during the storage period, using intact containers. Regularly sent to Shenyang City Industrial Solid Waste Disposal Center for harmless treatment.
6. Self-inspection of the implementation of emergency measures
Before the trial production, our company formulated the "Accidental Emergency Rescue Plan" and reported to the relevant departments of the Development Zone for the record. For each dangerous and pollution-prone part, we have made a plan (11 Specialized Emergency Disposal Points), and established an emergency disposal leading group with fire-fighting group, security group and medical group, and the responsibility is carried out to the specific person in charge (3.1 Emergency Organizational System).
Established an emergency accident pool (located ...). Necessary emergency equipment (dry powder fire extinguishers, sand and soil) are equipped in the places where hazardous chemicals are produced and stored, and emergency disposal drills and first aid training for the injured are carried out every year. Establishment of environmental hazards investigation ledger.
Through the self-inspection activities, it is confirmed that our company's safe production is running smoothly, and no environmental hazards that may lead to major production accidents and personal injury accidents have been found. Now, according to the instructions of the Environmental Protection Bureau of the Development Zone, we are revising the "Accident Emergency Rescue Plan" to improve the emergency rescue plan and management system for each dangerous and pollution-prone part.
Shenyang Certain Chemical Co.
April 6, 2012