Full-automatic filling machine operation and maintenance:
1. The liquid bottle to be filled is placed upside down on the work basket, check the liquid bottle should be flush with the lower mouth.
2. Put the vacuum basket in the vacuum filling, cover the quick-open can lid and lock it tight.
3. Close the air release valve, liquid inlet valve, open the vacuum pump, adjust the real air conditioning connecting valve so that the vacuum (depending on the amount of test filling) to meet the process requirements, step on the foot pedal to make the liquid bottles to be filled under the mouth of the liquid insert.
4. Slowly open the liquid inlet valve, the level of liquid in the pot rises, and at the same time open the drain valve, so that the liquid level to maintain the level of liquid between the provisions of the sight glass.
5. When the vacuum gauge pointer is at 0 state, proving that the filling liquid to complete, return the foot collapse plate, you can open the quick-open can cover to remove the liquid bottle is also filled.
6. Troubleshooting of vacuum mercury see (XD series but the level of rotary vane vacuum pump instruction manual), the vacuum pump is not used for a long time (more than seven days), the mercury should be used in the oil release, and new oil flushing, new, a preventive oil water corrosion of the pump body.