What are the outline, characteristics, model, selection and ordering information of ZK series combined air-conditioning units? Please answer in detail if you know?

ZK? series combined air-conditioning unit, mainly by the air mixing section ﹑ primary filtration section ﹑ fan section ﹑ table cold section ﹑ heating section ﹑ humidification section ﹑ shower section ﹑ wind adjustment section ﹑ second return air section ﹑ in the section ﹑ silencer section ﹑ corner section ﹑ air supply section and other basic functions of the section combined into

. Has a full range of functions, flexible selection, compact structure, beautiful appearance, excellent performance and other advantages. The air can be cooled, heated, humidified, filtered and other processing. Widely used in electronic instrumentation, precision machinery manufacturing, textile, chemical fiber, cigarette, pharmaceutical, food

, power station, light chemical and other industrial purification air conditioning; also used in commercial buildings, hotels, supermarkets, theaters, restaurants, hotels, office buildings, and other commercial and civil large and medium-sized public **** building comfort air conditioning.

ZK combined air-conditioning unit features

Combined air-conditioning unit features: AOER series combined air-conditioning unit, is a kind of water as the refrigerant, water or steam as the heat medium,? Functional sections as a combination of units in the air-conditioning equipment, can complete the air mixing, filtration, purification, sterilization, transportation, cooling, heating, dehumidification, humidification, anechoic and other functions. Combined air-conditioning unit is widely used in electronic instrumentation, precision machinery manufacturing, textiles, cosmetics, thermal power plants, nuclear power plants, light chemical industry, hotels, exhibition halls, office buildings, warehouses, shopping malls, entertainment venues, clean rooms, hospitals, laboratories, schools, libraries, conference rooms, cafeterias, restaurants, computer rooms and other industries and places; a wide variety of forms, models, AOER air-conditioning with advanced air-conditioning technology and new design ideas. AOER air conditioning has advanced air conditioning technology and new design ideas, scientific and rigorous work attitude and advanced research and development means to meet a variety of conditions, complete models, structural forms of combined air-conditioning units, AOER air conditioning production of combined air-conditioning units, including standard combined air-conditioning units, combined purification air-conditioning units and a variety of special specifications for combined air-conditioning units. AOER's combined air-conditioning units are characterized by beautiful appearance, high heat exchange efficiency, reasonable structure, good strength, low air leakage rate, low noise, smooth operation, good anti-cold-bridge measures, good heat preservation, easy installation and maintenance, safety and reliability, etc. They are suitable for various comfort central air-conditioning systems and clean air-conditioning systems. Here are more words and pictures to see/

Special Requirements: In order to meet the needs of different customers, AOER air conditioning at any time to provide non-standard or special configuration of the model's performance parameters and dimensions; in order to meet the customer's different requirements for the control of the unit, AOER air conditioning according to the customer's needs to provide a start-up control system, automatic control system and microelectronic control system ...? The frame of the unit adopts high-strength and high-quality aluminum alloy profiles and special aluminum alloy three-pronged head joint, which is beautiful in appearance, light in weight, and will never rust and corrode. Aluminum profile is closed hollow section, superior strength and heat preservation performance.

●? The panel is a double-layer plate structure, the outer plate is high-quality color steel spraying, the inner plate is galvanized steel, the middle layer of insulation materials for the high-pressure foam rigid polyurethane, its sound insulation and thermal insulation properties are better than the general insulation materials, and its thermal resistance of up to 1m2K/W. No condensation phenomenon outside the unit when working.

●? The heat exchanger is processed by American "OAK" equipment, with high heat transfer efficiency and stable and reliable quality. All heat exchangers have passed 1.6MPa pressure test

●? The fan adopts the excellent performance and low noise centrifugal fan in the domestic market, with large air volume, high wind pressure, low noise and low energy consumption, light weight, small system, long life, easy installation and maintenance, and the bearings are imported.

●? The unit is equipped with a wide access door, the access door chain for the whole aluminum alloy castings, durable, beautiful appearance, open and light, door locks for the pull type automatic tightening locks, door sealing performance is reliable.

●? The muffler is a metal orifice plate muffler with small internal resistance, low regenerative noise and excellent wide-band acoustic performance.

●? The dampers are made of specially designed high-quality aluminum alloy profiles with open blades and sealing rubber strips on the blades, which have a solid and tight structure and beautiful appearance, and can be equipped with manual and electric controllers to accurately control the air volume and adjust it arbitrarily.

●? Stainless steel water tray, bright and clean, durable, never rust.

●? There are lighting and observation windows in the fan section and drenching section. Differential pressure meter or air micro differential pressure display alarm can be set in the filter section as needed.

Combined air-conditioning unit modeling instructions

Note:

1.? Structure type judgment?

Right air-conditioning unit: the person facing the operating surface, the air flow to the right for the right air-conditioning unit, expressed in Y. The right air-conditioning unit can be used for the right air-conditioning unit.

Left-type air conditioner: people face the operating surface, the air flow to the left for the left-type air conditioner, expressed in Z.

2.

2. Operating surface regulations

1.? Supply and return fans on the side of the motor;?2.? Filter access door side;

3.? Hot and cold media in and out of the pipe and condensate discharge side;?4.? Instrument measurement hole and observation hole side.?

Combined air-conditioning unit selection and ordering

The designer (or user) must provide the factory with air-conditioning unit ordering reference schematic design, and indicate the model number, section number, left (Z) right (Y) type, and the form of the blower (S-type or C-type).

The indoor environment of this unit is t=5~40℃, F<90%.

This unit does not need to set up a cement foundation, only on the level ground (or floor) laying 2 to 4 10 # channel steel can be (channel length and combined air conditioning unit is the same). Channel steel provided by the user. Air conditioning unit should be laid around the drain (or floor drain).

The unit does not come with power control box and lighting distribution cabinet, but if the user needs, can be specified in the order. Air conditioning set of power supply into the hole location must be specified in the order (unspecified always according to the base plate into the supply line).

Supply and return air section, spray section, humidification section, filter section are equipped with lighting, the lighting power supply is 36V, the user is responsible for the power line to the air conditioning unit supply section of the top terminals. The power supply of the motor of the fan section is 380V, 50Hz, and the user is responsible for connecting the power line to the motor of the fan section.

The fan parameters and motor parameters listed in the table of the supply and return fan section in this sample are provided by the user according to general practice. The table is expressed in rated values. When the table in the air volume, wind pressure parameters can not meet user requirements, you can change the fan speed to change the fan's air volume, wind pressure (but the fan model can not be changed only according to the fan model indicated in the table selection), the specific air volume, wind pressure and other parameters and the corresponding motor model, power and other parameters should be specified in the order.

The air supply section and mixed return air section should be specified in the ordering reference diagram of the location and size of the air outlet (top air outlet, end air outlet both).

Surface cooling section and heating section should indicate the number of rows, cooling and heating medium parameters in the ordering combination diagram; spray section should indicate the number of rows.

Humidifier should indicate the manual or electric and humidification volume size.

The air supply section, the air supply and return fan section, the flat-top air distribution section, the mixing (return air) section and the secondary return air section are equipped with measurement or observation holes on the operation surface, if the user has any special requirements for the additional measurement holes and observation holes, please put forward at the time of ordering.

Accessories such as dampers outside the unit are not supplied by the factory, if users need them, please specify when ordering.

Ozone is a strong oxidant, bacteria, viruses and microorganisms have a strong ability to kill, can kill hepatitis and influenza disease. In order to meet the needs of medical and health care, biochemical pharmaceuticals, food and catering and other users, we can increase the ozone generation section in the air-conditioning unit, according to the different

users,? Provide different ozone concentration, specify in the order, our factory can meet the requirements.