1) If the equipment is installed on a platform, please pay attention to the strength of the installation platform, and there can be no * * * vibration problem.
2) The four mounting fulcrums of the equipment must be on the same horizontal plane.
3) The distance between the equipment and other objects should be at least 100 mm..
4) The connection between the equipment and the upper and lower process equipment must be flexible. Please pay attention to the material
Second, the daily maintenance of equipment:
1) When the equipment runs for the first time, the first 7 working days are the trial operation stage of the machine. Please check the equipment every day and set it according to the trial operation stage.
Adjust the regular inspection time according to the equipment situation. The scope of inspection includes: the fastening degree of fastening bolts of all parts (such as flange bolts, motors, etc.)
Fastening bolts), filter screen (sieve plate) whether fatigue and damage.
2) During the shift change (8 hours/shift), the staff shall tighten the fasteners (flange bolts and bottom grid bolts); 3) In strict accordance with the operating instructions of the vibration motor, regularly and reasonably replenish the lubricating grease. The bearing is made of 3# Great Wall lithium grease, please check and maintain it every 300 hours.
4) Installation of vibration motor: The vibration motor shall be installed with a torque wrench, and it shall be noted that each fixing bolt cannot be tightened at one time.
Set it up and tighten it to the best condition many times on average. The fixing bolts are 8.8-grade high strength bolts.
5) Check the screen in each shift. It is suggested to judge the service life of the screen by using it, and check the screen regularly during the critical period.
Replace. Case: The service life of two consecutive screens is 40 days. It is recommended to change the screen within 35 days.
Four, the common equipment fault solution:
1) The seal is damaged quickly:
Observe whether the collar is locked-tighten the collar bolt.
There are signs of movement-tighten the flange bolts.
The material has temperature-the replacement seal is made of high temperature resistant seal.
2) The screen is easily damaged:
The screen is not tight-replace the adjustment screen
Uneven blanking-change blanking mode or install distributor.
More blanking in an instant-change the blanking mode or install the distributor.
There are foreign objects in the material-pay attention to the control of the previous process.