Qinyuan water boiler 3kw manual

Product Description:

High quality recommended Goepe AdWords

Small / 0.5T / H reverse osmosis equipment

Automatic integrated water purifier

Manufacturer of water purification equipment, industrial optics with ultrapure water equipment

Integrated car wash water treatment equipment

Classification introduction of the water boiler

Continuous electric water boiler features

1, configured with computerized water boiler controller, the boiler runs intelligently, digitally, automated and humanized. From 10 ℃ to 100 ℃ water temperature can be set at will, the boiler can supply both boiling water and hot water, to achieve the dual-use machine.

2, the use of advanced ceramic electric heating tube, jacket high-quality seamless steel pipe, can effectively prevent scale interference, long service life. Heat-absorbing structure using computer-optimized design, fully optimized heat transfer coefficient of the heated surface, the thermal efficiency is very high, up to 98% or more. Greatly reduce power loss.

3, boiler intelligent control of water temperature, boiler to boil water, heating automatically stop; controller screen large font display water temperature, external glass tube water level meter, furnace water temperature, boiler water level is clear.

4, the boiler is designed as a normal pressure furnace, the top of the furnace body is equipped with atmospheric air vents, the boiler is in a non-pressurized state, there is no security risks. Users can be based on water demand, set their own on and off time, not only to meet user requirements, but also energy saving, reduce the cost of use.

5, the boiler automatically replenish water to reach the full state of water, replenishment of water automatically stops, without the need for special guards, time-saving, trouble-saving, energy-saving, labor-saving.

6, reliable boiler "water and electricity separation" structure, to prevent accidental leakage of electric heating tubes due to the user and staff safety hazards, while the boiler can not be discharged in the case of heating parts can be repaired, replaced, maintenance.

7, the use of high-precision water level sensor for real-time monitoring of the water level, the sensor adopts the pulse intermittent detection to determine whether the water level in the boiler is normal, in the case of the outlet temperature to reach the boiling water, the boiler is automatically filled with water one after another, the boiler can be a constant supply of continuous supply of 100 percent of the fresh boiling water.

8, the whole machine is equipped with overheating protection (furnace water temperature is too high, the burner automatically stops working and beeping alarm, secondary overheating protection (boiler shell temperature exceeds 105 ℃, automatically cut off the secondary circuit), anti-dry boiler water shortage protection (furnace water below the very low level, the boiler stops working and beeping alarm), boiler leakage protection (the control system detected leakage of electrical appliances, short circuit, will automatically cut off the power supply). will automatically cut off the power supply).

9, the use of aluminum foil centrifugal glass wool multi-layer heat preservation and high-quality white color steel plate for packaging, heat loss, beautiful and rust-resistant.

Heat storage type electric water boiler features

1, automatic computer control, can be set in the time automatically work, no need to operate, reduce heat loss, energy saving, reduce operating costs.

2, economic electric thermal storage water boiler to take full advantage of the night trough electricity to boil water automatically, in the daytime peak electricity supply for the user to boil water, the grid has played a role in cutting the peaks and filling the valleys, the valley tariffs are very cost-effective, and greatly reduces the boiler's operating costs.

3, the boiler electric power is small, generally do not need to increase the capacity of electricity, reducing the user's basic investment.

4, the use of advanced ceramic electric heating tube, jacket high-quality seamless steel tube, can effectively prevent scale interference, long service life. Heat-absorbing structure using computer-optimized design, fully optimized heat transfer coefficient of the heated surface, the thermal efficiency is very high, up to 98% or more. Greatly reduce power loss.

5, the boiler automatically replenish the water to reach the full state of water, replenish the water automatically stops, without the need for special guards, time-saving, trouble-saving, energy-saving, labor-saving.

6, boiler water storage capacity, without adding another holding tank can fully meet the needs of users throughout the day drinking water.

7, Chinese, animated liquid crystal display, the operating state at a glance, digital control temperature, display temperature, can ensure that the drinking water clearly. 8, electromechanical integration, compact and reasonable structure, installation and commissioning is very convenient.

9, the use of aluminum foil centrifugal glass wool multi-layer heat preservation and famous white color steel plate for packaging, heat loss is less, beautiful and rust-resistant.

Steam boiler

A structure

This product is made of 3042B stainless steel plate and stainless steel tube, non-toxic, no odor, in line with the national drinking water health standards. Among them, MJD type adopts cotton type perlite cotton as insulation material. The product is equipped with thermometer, liquid level meter and water faucet, which is convenient to observe its temperature and water level condition. When working, the cylinder has no noise, no pressure, and is extremely safe to use. The roughness of the polished surface can be more than 6.3um, and the product is equipped with drainage holes, which is very convenient for removing dirt.

Structure

Two, the use of methods and precautions.

1, in accordance with the schematic diagram, connected to the in and out of the gas pipe, the top cover ventilation pipe, pay attention to the top cover ventilation pipe, forbidden to use the valve, to keep the ventilation unimpeded.

2, close the drain, outlet, open the water inlet valve, so that the furnace is filled with water, more than the water level, the overflow port automatically overflow.

3, open the inlet pipe, the steam pressure control within 4.0-8.0kg/cm2, using this equipment can adjust the valve on the steam pipe piping to control the steam flow.

4, cold water calculated temperature room temperature, boiling water temperature of l00 ℃, generally about 45 minutes the water is boiling.

5, the product should always keep clean and hygienic, do not move collision, so as not to affect the service life. 6, this product stainless steel coil **** high working pressure of 0.875MPa, in the installation if the steam pressure is too high, can be installed in front of the steam inlet pipe pressure reducing valve. At the same time, in order to remove condensate as soon as possible, the return pipe should be installed at the trap

MJD-type automatic continuous steam boiler specifications of the energy table

(2) type of continuous steam boiler

I. Advantages

Full-automatic continuous steam boiler in the type of hand-controlled intermittent based on the addition of an automatic control device, automatic water intake, through the electronic control box power supply. After starting, steam solenoid valve sensor, steam system are fully automatic operation. Water heating to boiling water automatically shut off steam, water temperature below 95 ℃ automatically open the steam valve. Real full-automatic continuous supply of boiling water, the whole machine has an automation mode, without manual operation.

Two, structure

This product is made of food-grade 304 stainless steel plate and stainless steel tube, non-toxic, odorless; in line with national drinking water health standards, insulation using cotton perlite cotton as insulation. The product is equipped with electric control box, solenoid valve, sensor, temperature meter, water level meter, steam system are designed to run fully automatic. Operation of the cylinder without noise, no pressure, the use of extremely safe and reliable. Third, the performance

Cold water into the tank, through the tank steam coil will be rapidly heated to boiling water state, while the temperature control probe synchronized signal feedback to the temperature control valve, cut off the steam equipment in static, at this time you can let go of the water. In the release of water at the same time, cold water synchronized replenishment. When the water released to a certain amount of open water, the tank water temperature due to cold water replenishment, will gradually reduce the temperature control probe in the water temperature began to fall within the first time, the signal will be fed back to the temperature control valve, the temperature control valve quickly respond to open the steam, so that the temperature inside the tank is always constant at the set temperature.

Four, the use of methods and precautions

1, in accordance with the schematic diagram, connected to the air inlet pipe, condensate pipe and water inlet pipe, start the power supply can be normal operation.

2, the top cover ventilation pipe is strictly prohibited with a valve or sealing, to keep the ventilation pipe unobstructed.

3, because the water is heated by the steam coil, the normal heat upward, the temperature gauge is set in the middle of the boiling water furnace cylinder. So when the temperature gauge shows 100 ℃, the water temperature at the bottom of the boiling water furnace has not reached a certain temperature. So the first run of the boiler to be a little longer, to be in the cylinder boiling and tumbling conversion in order to make the bottom reach a certain temperature. After normal operation there is no phenomenon of the bottom of the water temperature is not high.

4, the product of stainless steel coil *** high working pressure of 0.875MPa, coil steam pressure control in 4.0-8.0kg/cm2, steam pressure is higher in front of the steam inlet pipe to install a pressure reducing valve. Condensate pipe should be installed to prevent air and trap.

5, cold water calculated temperature for room temperature, boiling water temperature of 100 ℃, the normal 45 minutes or so the water will boil, such as special requirements can increase the heat transfer area to shorten the time.

6, operating procedures:

①Turn on the power (AC220V), check the solenoid valve, temperature control probe connection is good.

②Start the control box knob, the temperature control instrument began to work, such as the temperature is less than the desired temperature setting value, the solenoid valve open work; such as the temperature reaches the desired setting value of the solenoid valve closed.

③Temperature controller settings, according to the temperature controller panel adjustment button plus or minus can be.

(3) automatic separation of electric water boiler

I, product features

1, automatic separation of electric water boiler, the use of three-body separation structure, so that the absolute separation of raw water and boiled water, completely overcome the drawbacks of the mixture of raw water and boiled water together and have a rapid boiling water, belonging to the field of commercial appliances technology.

2, the water level is controlled by electric micro-control contacts. Safe and reliable, durable, energy-saving power saving, maintenance, scale clearing is simple and convenient, no need for personal management.

3, the use of waste heat, energy-saving measures to keep warm for a long time, without having to drain the water after the night.

4, product serialization for users to choose.

Full-automatic separated electric water boiler series specification model table:

Two, installation and use:

1, will be placed in a convenient location to use the water boiler, placed flat, with a hose connected to a good source of water, can be filled with cold water many times to clean, so as to avoid clogging of dirt.

2, cleaning is complete, fill the water to measure the cold water level line is in line with the requirements of the machine, if not, you can bend the float valve linkage, correct the water level, to meet the requirements. (The product has been debugged before leaving the factory, generally do not need to mobilize)

3, connect the power supply, in accordance with the requirements of the relevant safety regulations of the power supply department should be required to join the corresponding specifications of the leakage of power to protect the expansion of the switch in the circuit. The product shell is connected to the grounding wire as required.

4, according to the above requirements to test and check the correct power use.

5, with the electrical control schematic diagram.

Three, the principle of operation:

1, the water boiler with a hose connected to the water source, the water source into the cold water tank into the boiler, the water level rises, there is a float valve to control the height of the limit, the automatic shutdown of the water supply.

2, the water source into the cold water tank, cold water electric control ball and float, connected to the control circuit power.

3, turn on the power, the red light is on, showing that there is power. When the green light is on to show that the heating tube is working, about five minutes to start boiling water, while the cold water is also constantly replenished to the boiler, the formation of the work program.

4, boiling water boiler boiling water constantly overflowing into the open water tank, the water level rises, open water electric control float gradually rose to a limited height, disconnect the boiler heating tube to stop working. Green light off, when the water temperature in the boiling water tank low thousand 98 ℃ automatically open, this time the yellow light on.

5, boiling water by drinking, boiling water tank water level drops lead to electric control float down, then the green light is on, start boiling water.

6, according to the above principle, the water boiler form the above program control function to achieve fully automatic cycle work, no need for personal management.

7, due to other reasons for failure, the water boiler is equipped with cold, boiling water, overflow pipe, the water will overflow from the pipe, will not cause damage, should be checked and repaired in time.

8, due to water cut off, cold water electric control ball and drop to a limited position, will automatically cut off the control circuit to stop the work system, such as long-lasting water shortages and deactivation should be cut off from the main power supply, the water boiler to implement protection.

Four, maintenance, overhaul

1, this product is fully automatic control, connecting water, electricity, water tank that is run according to the degree, but a long time without water, in order to protect and extend the life of electrical appliances should be cut off from the main power supply.

2, due to different water quality around the world, regularly on the electric heating pipe, boiling water pipe, overflow pipe and boiling water float to clean up the scale, clearing the scale should not be knocked, collision.

V. Troubleshooting and overhaul

1, cold water overflow, you should check whether the float glazed core failure.

2, open water tank overflow should check whether the open water electric control float failure, that is, floating position. Also check whether the float box outside the microswitch is damaged.

3, the boiler does not boil water, check whether the power supply is connected, whether the cold water tank is water control float floating (if the float leaks into the water, also does not float, replace the float can be. If the front are good, and then measure whether the electric heater burned out.

4, the water temperature is not open, check the water inlet valve mouth whether there are impurities stuck, can not close the water, resulting in not much water. It will form the water temperature is not open cause. However, the insulation function is out of order, whether the insulation pipe is damaged or poor switch contact.

5, the indicator does not show, check the line and the indicator bulb.

Sixth, after-sales service

1, where the purchase of our products, due to quality problems arising from the failure of the factory is responsible for the maintenance, replacement, product warranty period of six months, the warranty period charged by the electric heating pipe fee.

2, due to the user's improper use of equipment damage, according to the actual situation of the charge for materials and accessories.

3, the user in the self-maintenance difficulties can be contacted at any time by phone, our factory staff guidance, but also training personnel.