Technical parameters Measurement accuracy Repeatability Conductive media <2mm Non-conductive media <50mm
Temperature range Temperature of the media -200 ℃ ∽ +800 ℃ (select the appropriate sensor probe)
Ambient temperature -40 ℃ ∽ +60 ℃ Storage temperature -40℃∽+60℃
Response time 0.3s or 0∽20s continuously adjustable
Sensitivity Better than 0.3PF
Temperature effect ±0.05PF per 10℃
Signal output DPDT relay output, two groups of normally open, normally closed contacts, contact capacity: AC200V5A DC24V5A
Power supply 220V AC or 24V DC
Power consumption 4W
Protection class IP66
Process connection External thread G3/4″, G1″
Flange GB-9123-2000 DN50 PN0.6MPa
Sensor electrode Extended rod type The longest 3m, the shortest 0.4m, material stainless steel 304 + PTFE plastic, ceramic, or other agreed requirements.
Cable type Maximum length 35m, minimum 0.5m, material stainless steel 304 + PTFE plastic, ceramic, or other agreed requirements.
Protection electrode Standard length 100mm or 300mm Material stainless steel 304+PTFE plastic, ceramic or other requirements as agreed.
Housing A plastic PBTP
B die-cast aluminum, epoxy resin coating
Cable introduction hole M20x1.5 with plastic cable sealing sleeve
Explosion-proof standard ExdIICT5 MAT700 Continuous Level Meter Power supply A 24VDC two-wire system Range of application2 Normal media3 Strongly conductive media Mode of action4 Level mode5 Distance mode Sensor See MAT700 for more details. Distance mode Sensor See MAT700 Sensor Selection Chart Installation I Integral mounting R Split mounting Explosion-proof E Yes Z No