Laser marking machine light is sometimes big and sometimes small how is it

Recently read some laser marking machine maintenance knowledge, just can help you help ha

You should exist in the following aspects of this phenomenon:

1, the laser resonance cavity is not change: fine-tune the resonance cavity lenses, so that the output spot is the best;

2, the full reverse and the output diaphragm whether there is a phenomenon of contamination occurs;

3, the acousto-optic crystal cheap Or acousto-optic source output energy is low: adjust the acousto-optic crystal position;

4, the cooling water tank temperature settings and the ambient temperature temperature difference of more than 5 degrees;

5, krypton lamp service life to the period;

6, into the vibration mirror laser deviation from the center: adjusting the laser;

7, if the current is adjusted to 20A or so, still feel the light intensity does not shut down: the krypton lamp aging . Replace the new lamp.

I hope that Chongqing Haitong marking machine reply can help you, if you still have questions about the place, you can directly at www.baidu.com上搜索 "Chongqing Haitong marking machine" and contact us!