In the traditional method of measuring the center thickness of optical components and optical lenses, there are many factors that will affect the precise centering of optical lenses. It is difficult for traditional center thickness measurement equipment to accurately determine the center of an optical lens, so it is impossible to accurately measure its center thickness. In addition, the lens will be scratched during the process of finding the center.
HANCOCK CT200 perfectly solves these problems. Through the self-centering of the three-jaw chuck and the height measurement with the digital display indicator, it can solve the scratches caused by finding the center point position in the traditional measurement method. With the addition of the digital display indicator, It has high precision and can measure the center thickness with high precision, achieving a measurement accuracy of 1 micron. With the improvement of imaging quality requirements for lenses and other products, higher requirements have been put forward for the accuracy of medium-thickness detection. More and more lens specifications require accuracy requirements for center thickness below 10um. HANCOCK CT200 needs to be used to cooperate with your processing. Machine to complete.
1. Measurement accuracy
Resolution:?0.0005?mm?Accuracy:?≦?0.002?mm?Repeatability:?0.001?mm
2. Measuring stroke: 60mm
3. Measuring diameter: 10-200mm
4. Air pressure: 6bar?