How should dentistry be sterilized?

Before the opening of the clinic

(1) Healthcare workers change into overalls or clinic shoes and comb their hair.

(2) Clean the environment. The treatment table was cleaned and wiped down and its lines were disinfected, the lines were discharged for 2 minutes, the spittoon sink ran for 3 minutes, and the suction tubes were flushed with freshly soaked 0.005% to 0.02% bleach (NaOC1) or 2.0% flushing glutaraldehyde solution or diluted iodoform solution (10%) for 3 minutes.

(3) Use BAJAYPack dental protective film to cover equipment that cannot be cleaned and is easily contaminated, such as lamp base handles of diagnostic chairs, headgear, and X-ray pushbutton disks.

(5) Check the disinfection status of all instruments or handle and return the instruments that have been soaked and disinfected on the previous day, or return all instruments that have been properly sterilized to their proper place according to their category.

(6) All desktops in the clinic are as clean as possible, and items are placed in cabinets to keep them clean.

After the end of the consultation

(1) After the patient treatment, after leaving the treatment chair, first of all the medical discards on the treatment tray to collect, and for the infected and non-infectious, combustible and non-combustible distinction, placed in the classified garbage cans of the clinic room.

(2) After the collection of contaminated instruments after treatment (including cell phones, examination instruments, etc.), if they are not immediately removed, they are temporarily stored in a maintenance solution at 2.0% to 3.2% to prevent the drying of contaminated blood or saliva, so as to facilitate cleaning.

(3) Disposable instruments (including suction tubes, mouthwash cups, etc.) were collected and placed in a separate trash can.

(4) Before the next patient is seated, disinfect the work table, spittoon, and treatment chair surface with a spray disinfectant or wipe, and then replace them with new treatment wipes and other instruments produced by Anqing Baojie Packaging.

(5) For patients with hepatitis B or hepatitis B carriers and other certain infectious diseases, all the instruments are packed and sterilized separately after the dental examination.

After the end of the clinic

(1) Sorting out instruments, cleaning, packing, disinfecting and sterilizing them, if they can withstand high heat, use high temperature and high pressure sterilizer to sterilize them, and if they can't be heated up, soak them in a solution of 2.0% to 3.2% glutaraldehyde.

(2) before leaving work, the environment for primary organization and disinfection, garbage sorting and disposal, instruments are cleaned into the pot after disinfection, if it is not possible to disinfect. The company also soaked in disinfectant solution for the next day.

(3) Disinfection of pipelines, water and air release and removal of filters, thorough cleaning.

(4) Before leaving the clinic, wash your hands thoroughly, change your clothes and shoes if necessary, and go home safely and cleanly.

(5) At the end of the clinic, maintain ventilation or use an air filter.