Purpose: salt spray box, salt spray test chamber for artificial climate environment "three-proof" (hot and humid, salt spray, mold) one of the test equipment, is the study of machinery, national defense, light industry, electronics, light industry, electronic instrumentation and other industries a variety of environmental adaptability and reliability of an important test equipment.
Salt spray box salt spray test box performance refers to the temperature range room temperature +5 ℃ ~ 55 ℃ Temperature uniformity ≤ 2 ℃ Temperature fluctuation ≤ ± 0.5 ℃ Salt spray precipitation 1 ~ 2ml / h.80cm2 spray mode continuous, gap spray any choice Test Timing 1 ~ 999 (S, M, H) can be adjusted
Temperature control system for salt spray test box Controller microcomputer temperature integrated Controller Accuracy range Temperature ± 0.1 ℃ Temperature and humidity sensor Platinum resistance PT100Ω Heating system Nickel-chromium alloy electric heating type heater
Purpose: Applicable to electricians, electronics, instrumentation and other products, parts and materials in the complex high and low temperature hot and humid environment storage, transportation, use of complex high and low temperature hot and humid changes in adaptability test.
High and low temperature chamber performance indicators Temperature range A: -20 ℃ ~ 150 ℃ B: -40 ℃ ~ 150 ℃ C: -60 ℃ ~ 130 ℃ D: -60 ℃ ~ 130 ℃ Humidity range 30 ~ 98% R.H Fluctuation / uniformity ≤ ± 0.5 ℃ / ± 2 ℃ Temperature deviation +2%, -3% R.H Rising temperature time 2 ℃ ~ 3 ℃ / min (unloaded) Cooling time Time 0.7℃~1℃/min (no load) Hi-Low Temperature Humidity Chamber Temperature and Humidity Control System Controller Imported "TEMI300" microcomputer temperature and humidity integrated controller (temperature directly display percentage) Accuracy range Temperature ± 0.1 ℃, humidity ± 0.1% R.H., temperature and humidity sensors platinum resistance PT100 Ω heating system nickel-chromium alloy electrical heating system. Ω heating system nickel-chromium alloy electric heater humidification system external isolation type, all stainless steel boiler type shallow surface evaporative humidifier dehumidification system using the evaporator coil dew point temperature laminar flow contact humidifier water supply system humidification water supply with automatic control and can be recycled residual water, water consumption refrigeration system closed air-cooled single-stage compression refrigeration / the original French "Taikang" / closed air-cooled single-stage compression refrigeration / original France "Taikang "/ closed air-cooled compound compression refrigeration circulation system high temperature low noise centrifugal motor, multi-blade centrifugal wind wheel Use: for electricians, electronics, instruments and other products, parts and materials in the complex high and low temperature hot and humid environment storage, transportation, use of complex high and low temperature hot and humid changes in adaptability test.
Performance indicators Temperature range A: -20 ℃ ~ 150 ℃ B: -40 ℃ ~ 150 ℃ C: -60 ℃ ~ 130 ℃ D: -60 ℃ ~ 130 ℃ Humidity range 30 ~ 98% R.H Fluctuation / Uniformity ≤ ± 0.5 ℃ / ± 2 ℃ Temperature deviation +2%, -3% R.H Rising temperature time 2 ℃ ~ 3 ℃ / min (unloaded) Cooling time 0.7 ℃ ~ 1 ℃ / min (no load) /min (no load) Temperature and humidity control system Controller Imported "TEMI300" microcomputer temperature and humidity integrated controller (temperature directly display the percentage) Accuracy range Temperature ± 0.1 ℃, humidity ± 0.1% R.H., temperature and humidity sensors Platinum resistor PT100 Ω Heating system Nickel-chromium alloy heater electric heater Humidification system External isolated, stainless steel boiler type shallow surface evaporative humidifier Dehumidification system using the evaporator coil dew point temperature laminar flow contact humidifier Water supply system Humidification water supply with automatic control and can be recycled water, water conservation and consumption reduction Refrigeration system Fully enclosed air-cooled single-stage compression refrigeration / the original French "Taikang" / fully enclosed air-cooled compound stacked Compression refrigeration Circulation system High-temperature and low noise centrifugal motor, multi-leaf centrifugal wind turbine Box material Outer box material High-quality A3 steel plate, the surface of the phosphate electrostatic spraying Inner box material SUS304 stainless steel high-quality 2B-grade light board Insulation material Ultra-thin ultra-fine glass fiber Door frame insulation Double-layer aging-resistant silicone rubber door seals Hi-Low Temperature Alternating Humidity and Thermal Test Chamber Usage
Can accurately simulate the low-temperature, High temperature, high temperature and high humidity, low temperature and low humidity and other complex natural environments, suitable for plastics, electronics, food, clothing, vehicles, metals, chemicals, building materials and other industries, product reliability testing.
High and low temperature alternating humidity test chamber performance indicators Temperature range A: -20 ℃ ~ 150 ℃ B: -40 ℃ ~ 150 ℃ C: -60 ℃ ~ 150 ℃ D: -60 ℃ ~ 150 ℃ Humidity range 20 ~ 98% R.H Fluctuation / Uniformity ≤ ± 0.5 ℃ / ± 2 ℃ Temperature deviation +2%, -3% R.H Rising temperature time 2 ℃ ~ 3 ℃ / min (no load) Cooling time 0.7℃~1℃/min (no load)
High and low temperature alternating humidity test chamber temperature and humidity control system Controller Imported "TEMI880" microcomputer temperature and humidity integrated controller (temperature directly display the percentage) Accuracy of the range of temperature ± 0.1 ℃, humidity ± 0.1%R.H, temperature and humidity Sensor platinum resistance PT100Ω Heating system nickel-chromium alloy electric heating heater Humidification system external isolation, all stainless steel boiler type shallow surface evaporative humidifier Dehumidification system using the evaporator coil dew point temperature laminar flow contact humidifier Water supply system humidification water supply with automatic control and can be recycled residual water, water consumption Refrigeration system fully enclosed air-cooled single-stage compression refrigeration / original France "Taikang"/totally enclosed air-cooled compound compression refrigeration Circulation system High-temperature and low noise centrifugal motor, multi-blade centrifugal wind wheel
High and low temperature alternating humidity and heat test box box material Outer box material High-quality A3 steel plate, the surface of the phosphating static spraying Inner box material SUS304 stainless steel high-quality 2B-grade light board Insulation material Ultra-thin glass fiber door frame thermal insulation Ultra-fine glass fiber door frame insulation Double-layer high and low temperature aging silicone rubber door sealing strip Use:
This equipment is suitable for product parts and materials for cold and thermal shock test. Applicable to electronics, electrical products and other military equipment in the surrounding atmosphere under conditions of drastic changes in temperature adaptability test, but also the screening of electronic components in the initial failure of the best equipment.
Technical parameters:
1 Specimen workspace size: 1352 × π × 240
2 Temperature upper limit: +150 ℃
3 Temperature lower limit: -60 ℃
4 Temperature deviation: ± 1 ℃
5 Temperature fluctuation: ± 0.5 ℃
6 Temperature recovery time: 5min
7 temperature recovery conditions: high temperature +80 ℃ insulation ≥ 30min, low temperature -70 ℃ insulation ≥ 50min, the weight of the specimen in the specified range
8 specimen transfer time ≤ 15 seconds
9 specimen transfer using pneumatic
10 specimen weight: ≤ 2.5kg
11 high temperature temperature greenhouse heating time: 30min (+25 ℃ ~ +100 ℃)
12 low greenhouse cooling time: 60min (+25 ℃ ~ -70 ℃)
13 Noise: (dB) ≤ 65
14 Power supply: AC380V/50Hz + protective grounding
15 Total power: 10.5KW Use:
This product is suitable for electricians, Electronics, instrumentation and other products, parts and materials in the high and low temperature environment, storage, transportation, use of adaptability test.
High and low temperature chamber parameters:
Workshop size: 1000 × 1500 × 1000
Temperature range: -20/-40/-60/-70 ℃ ~ +100/150 ℃
Temperature fluctuation: ≤ ± 0.5 ℃
Temperature uniformity: ≤ ± 2 ℃
Temperature reduction rate: 0.7~1℃/min (no load)
Heating rate: 2~3℃/min (no load)
Noise (dB): ≤65
Power supply: AC220/380V 50Hz
Usage:
Used to simulate the environment of the electrician, electronics, automobile parts, and other products and goods in the transportation process. In the process of transportation environment, test the vibration resistance performance of its products. Realize the vibration test needs all the functions: sine wave, frequency modulation, frequency sweep, programmable, octave, logarithmic, maximum acceleration, amplitude adjustment, time control, full-function computer control, simple fixed acceleration / fixed amplitude. Equipment through continuous trouble-free operation for 3 months test, stable performance, reliable quality.
Product structure:
1. Maximum test load (kg): 100 (customized according to user needs)
2. Frequency range (0.01Hz): 1Hz ~ 400Hz, 1Hz ~ 600Hz, 1Hz ~ 3000Hz, 1Hz ~ 5000Hz (can be adjusted arbitrarily) 3. Sweeping range (0.01Hz). 1Hz~400Hz, 1Hz~600Hz, 1Hz~3000Hz, 1Hz~5000Hz (adjustable) 4. Amplitude (adjustable range mmp-p): 0~5mm
5. Maximum acceleration: 20g
6. Vibration direction: ①vertical ②horizontal ③vertical+horizontal
7. Vibration waveforms: sine waves
8. Programmable (0.01Hz): 1-15 sections of each section can be set at any frequency and time, can be recycled
9. Multiply the frequency (0.01Hz): 5 sections of the multiplier ① low to high frequency ② high to low frequency ③ low to high and then to the low frequency / can be recycled
10. Power: 2.2Kw
11. vibration table size L * H * W (cm): 50 * 50 (cm): 50 * 50 (cm): 20g
12. (cm): 50 * 50 (can be customized according to user requirements)
12. table size L * H * W (cm): Vertical: 50 * 20 * 50 Horizontal: 50 * 25 * 50
13. power supply voltage (V): 220 ± 20%
14. maximum current (A): 10
15. time control: programmable FM, sweep, frequency, frequency, logarithmic can meet the standard time settings
16. Function control: full-featured computer control with computer and printing, connecting the computer to do the control, storage, recording, printing functions Purpose:
This product is designed to test the product packaging by the fall when the damage is done, and evaluation of electrical appliances, electronic assemblies in the process of handling, suffered from the fall of the Impact strength. This drop test bench is equipped with high-precision digital display instrumentation to control the height. The automatic limit protector prevents the equipment from human damage. Power system: synchronized motor, speed precision. Motorized drop, easy to use, large acceleration. Motorized lifting, can be used for prongs, corners, surface testing, conducive to improving and perfecting the packaging design.
Technical parameters:
1, drop height: 400-1500MM 400-2000MM 2, the maximum weight of the test piece: 80Kg;
3, the maximum size of the test piece: 800 * 800 * 1000mm;\ 800 * 1000 * 1000MM
4, the size of the base plate: 1400 * 1200 *20MM;
5, motor power: 1.85kw
6, the test bench external dimensions: 1400-1200-2215mm; 1400-1200-2815mm
7, fall error: ± 5mm;
8, fall plane error <1 °
9, the height of the display is adopted High-precision encoder sensing
10, power supply: 380V, 3KW Main technical parameters:
1. Model: LYXD-R900
2. External dimensions: 900 × 950 × 1800 (depth × width × height) mm
3. Studio size: 470 × 750 × 460 (D×W×H)mm
4. Temperature range: room temperature +10℃~+120℃
5. Temperature fluctuation: ±0.5℃
6. Temperature uniformity: ±3℃
7. Humidity range: 30~98% R-H
8. Humidity fluctuation: ±3% R-H
9. Uniformity: ±5% R-H
10. Rainfall cycle: 0-999 minutes, adjustable
11. Xenon lamp power: 5.4KW
12. Xenon lamp life: 2000h
13. Distance between the sample holder and the lamp: 350~375mm
14. Heating power: 1.5KW
15. Humidifying power: 1KW
16. Sample plate: standard sample plate
17 . Irradiance wavelength: 300nm~800nm
18.Wavelength irradiance: 550W/M2
19.Nozzle water pressure: 1~1.5bar
20.1m noise: ≤80Db Technical specifications:
1 Workshop dimensions: 500×500×500 (depth×width×height) mm
2 Ozone concentration: 0~1000±5pphm
3 Temperature range: RT+10℃~+60℃±2%
4 Ozone concentration deviation: ≤10%
5 Temperature fluctuation: ±0.5℃
6 Temperature uniformity: ±2℃
7 Rotational speed of the sample holder: adjustable from 0.1~2 rpm
< p>8 Diameter of rotary disk: ¢450mm9 Clamps: 12 pairs (stainless steel) Technical parameters:
Temperature range: room temperature +10 ℃ ~ 200 ℃ (arbitrary adjustment)
Temperature uniformity (unloaded): ≤ ± 2 ℃
Temperature fluctuation: ≤ ± 0.5 ℃
Temperature increase rate: ≥ 3 ℃/min (unloaded)
Temperature uniformity: ± 2 ℃
Temperature increase rate: ≥ 3 ℃/min (no load)
Power supply: AC220V ± 10%, 50HZ Straight pipe rain test chamber of the main technical parameters:
1, water spray aperture: 1.2mm
2, nozzle aperture: 1.6mm
3, the number of spray holes: 40
4, the spray hole spacing: 12.5
5, the spray pipe rotation speed: 23 RPM
The main parameters of the pendulum rain test:
1, water spray hole diameter: 0.4
2, water spray hole spacing: 50mm
3, water spray ring radius: R375mm
4, water spray pipe diameter: 16mm
5, pendulum pendulum swing angle amplitude: 45, 60, 90
6, pendulum speed adjustment: stepless regulation Pendulum speed adjustment: stepless adjustment
7, rain water pressure: about 80Kpa
8, water flow water supply: 10 kg (can be customized according to user needs)
9, test bench speed: 1 ~ 17r/min Technical parameters:
1, temperature adjustment range: RT +5 ℃ ~ 60 ℃ (adjustable)
2, the metal mesh Nominal wire diameter: 50um
3, wind speed: ≥ 0 ~ 3.5m / s
4, the test box screen nominal wire diameter: 75 ~ 100 ūm (100 ~ 200 mesh)
5, blowing the dust cycle (intermittent control) is adjustable
6, talcum powder dosage: 2kg ~ 4kg / m3
7, the specimen electrical material port Parameter
1. Test bench speed: 1~17 r/min 2. Pendulum material ¢15mm stainless steel pipe 3. Spray hole: ¢0.4mm 4. Hole spacing: 50mm 5. Pendulum pendulum swing: ±45°/±60°/±90° 6. Drenching water pressure: 80~100kpa 7. Test bench: ¢800mm