Emergency plan for casualties

Casualty Accident Emergency Plan1

1. In the event of accidental casualties in the district, the security personnel should immediately go to the scene, find out the situation, and report to the manager of the security department or the general manager.

2. If the injured person has not died, should be in the protection of the scene at the same time immediately organize rescue, and notify the medical rescue center. The fracture casualty must pay attention to try not to move, to prevent the injury from worsening.

3. If the casualty is caused by electrocution, security personnel should be close to cut off the power supply or insulated (such as dry wood, bamboo or plastic, rubber will be the power supply away from the electrocuted, and then rescue. It is strictly prohibited in the absence of cutting off the power supply, with a hand directly to pull the electrocuted or with a metal pole to dial away from the power supply, in order to prevent their own electrocution.

4. If the casualty is caused by equipment failure or facility damage, the security department should immediately notify the manager of the Ministry of Engineering and Materials (or supervisor) to the scene, *** with the development of rescue programs.

5. If the casualty is caused by drowning, security personnel or other employees should immediately rescue, if the person who fell into the water to drink more water, should be allowed to head down upside down, press the abdomen, so that it spit out the water drunk, and artificial respiration if necessary.

6. If the casualty is caused by the fall of the upper floors, the objects smashed injuries, in the rescue of the injured at the same time, should protect the scene, take photos or videos, leaving witnesses, and at the same time to the police alarm.

7. If the casualty is caused by traffic accidents, should be in the protection of the scene, rescue the injured at the same time, record the vehicle, leaving the driver and witnesses, if there is a surveillance video, save the relevant video, reported to the police. If the traffic accident caused by traffic jams in the area, should open up sidewalks, actively divert traffic, and set up a cordon to prevent damage to the scene.

8. The injured were sent to the hospital rescue, should record the ambulance number, sent to the hospital and the injured.

9. Detailed records of accidental casualties. For casualties caused by equipment failure or damage to facilities, as well as electrocution accidents caused by the management company, the relevant departments in the incident within four hours to write a written report to the company's general manager, so that the company's general manager, depending on the situation, to report to the relevant parties and to find out the reasons for the implementation of the responsibility.

Casualty accident emergency plan 2

First, the type of accident and the degree of harm analyzed.

1, the type of accident.

(1) casualties caused by fire accidents.

(2) ladder table fall caused casualties.

(3) personnel casualties caused by electrocution.

(4) traffic accidents caused casualties.

(5) casualties caused by natural disasters.

(6) Injuries or deaths caused by robbery.

2, the degree of harm analysis.

Casualties, property damage. Personnel casualty accident emergency plan can be activated at the same time with other emergency plans that may involve casualties.

Second, the emergency organization personnel and responsibilities.

1, gas station manager (xxx) is responsible for the overall coordination and command of the scene.

2, gas station accountant (xxx) is responsible for communication, alarm contact.

3, the gas station vestibule supervisor is responsible for the scene to organize the personnel for on-site disposal.

4, the gas station other on-duty employees are responsible for the implementation of the field command of the deployment, to complete the task assigned.

Third, prevention and warning.

The discovery of dangerous situations, after the gas station on duty vestibule supervisor above any one of the management staff to confirm the danger, that is, to start the emergency disposal procedures. The gas station manager (or vestibule supervisor) should order the gas station accountant to report to different levels of superiors according to the situation on the spot and the development of the situation.

At the same time, call the police at 110, 119, 120, if the situation is expanding and the situation is urgent, we should contact the neighboring enterprises and the street offices of the nearby residential areas in a timely manner to inform the gas station of the emergencies, and ask for cooperation in evacuation and rescue.

(1) Types of emergencies (fire, gas leakage, fuel spillage, injuries, etc.).

(2) The name and address of the gas station.

(3) The name and phone number of the person who called the police.

Four, emergency measures.

(1) When the casualty is less serious, it can be dealt with on-site by the temporary medical team; fatal or serious injuries should be accounted for by the accountant to call 120 for help in a timely manner, and the on-site staff should assist the medical staff in sending the casualty to the nearest hospital for treatment.

(2) If necessary, stop the business and promptly report the situation to higher authorities.

V. End of emergency.

After confirming that the casualties have been properly placed, the station manager will report to the higher authorities and get the consent to terminate the emergency response procedures.

Six, emergency supplies and equipment security.

According to the gas station management specification equipped with fire equipment and materials, Wanli Le gas station should ensure the effectiveness of emergency supplies. At the same time relying on local social resources and joint defense organizations.

VII.

1. Drill requirements.

(1) At the beginning of each year, the southwest area of the company is responsible for the entire station staff for a special training on emergency preparedness. The training plan, materials, test papers should be reported to the higher authorities for approval and record.

(2) Before new employees start work, they must receive safety training from Miles Le gas station.

(3) The total time for safety training shall not be less than 40 hours, and the training shall be recorded. The examination is in the form of a closed book, chaired by the station manager. Those who fail the exam should be retrained.

2, plan revision and improvement.

Wanli Le gas station emergency response team to organize the revision of the special emergency plan. No special reasons, every year on the special emergency plan for a revision. If the following reasons should be revised in a timely manner:

(1) the promulgation and implementation of new laws and regulations or the implementation of the revision of relevant laws and regulations;

(2) through the emergency plan exercise or by the emergency test, found that there are defects or loopholes in the emergency plan;

(3) changes in the organization of the emergency plan or other reasons.

The revision of the plan must be approved by the parent company or the professional department to re-examine the risk evaluation approval before the implementation of changes.

3. The implementation of the plan.

Emergency Response Plan for Casualty Accidents3

1 General Provisions

1.1 Purpose of Preparation

In order to ensure that Gansu Hua'ao Railway Comprehensive Engineering Company Limited (hereinafter referred to as: the head office) in the event of personal injury and death of sudden accidents, can be rapid, orderly and effective emergency response action to effectively carry out the on-site disposal and rescue work, to Control the escalation of the accident, the maximum degree of prevention and protection of the lives of employees, the development of this plan.

1.2 Preparation of the basis

Based on the "People's Republic of China **** and the State Safety Production Law", "Construction Safety Management Regulations", "Reporting and Handling of Casualties and Injuries to Enterprise Employees" and "Regulations on the Protection of Labor in Places of Work Using Poisonous Substances" and other relevant laws and regulations.

1.3 Scope of application

This plan is applicable to the prevention and rescue of personal injury and death accidents in the company and workplaces.

1.4 Working Principles

1.4.1 Based on the principle of "prevention first, hierarchical management, hierarchical responsibility", early prevention, early control, early solution, eliminating all potential safety hazards.

1.4.2 Accident state follow the "people-oriented, rapid response, cooperation, each responsible for" principle, to minimize the impact and reduce losses.

2 organization and command and its responsibilities

2.1 The establishment of Gansu Hua'ao Railway Comprehensive Engineering Company personal casualty emergency response leading group (hereinafter referred to as: Headquarters Emergency Response Leading Group)

Leader: General Manager, Secretary of the Party Committee

Standing Deputy Leader: Deputy General Manager in charge of safety

Deputy Leader: Deputy General Manager in charge of safety

The General Manager: General Manager, Secretary of the Party Committee

Deputy leader: other members of the party and government team of the head office

Members: heads of departments, the entire safety department

The office of the leading group is located in the Department of Safety

2.2 Responsibilities of the Head Office Emergency Disposal Leadership Group

2.2.1 Responsible for organizing, coordinating, and directing the emergency rescue of personal injury and death accidents;

2.2 .2.2 Report the situation related to personal injury and death accidents to the higher authorities, and be responsible for supervising the implementation of the instructions and approvals of the higher authorities;

2.2.3 Be responsible for organizing the compilation and revision of emergency response plans for sudden personal injury and death accidents, guiding the relevant departments of the authorities and companies to compile emergency response plans, and coordinating the construction of emergency response information systems and emergency response platforms in the pipeline;

2.2.4 Be responsible for Supervise and inspect the emergency management work of each company, study and put forward to strengthen the company's emergency management work of opinions, recommendations;

2.2.5 guidance and coordination of the prevention and warning of special major, major sudden personal injury and death emergency drills, emergency response, investigation and evaluation, information dissemination, emergency security and publicity and training work.

3 Emergency Disposal

3.1 Information Report

Where the company's production and operation process and production management area of the casualty accidents, regardless of the cause, responsibility and casualties belonging to, must be implemented immediately the accident reporting system by the occurrence of accidents to the head office of the Department of Safety (railroad phone, 071-50257, 071-24495, fax: 071-24495), and form an accident overview (Labor Safety Supervision Report-3) within one hour to report to the Safety Department of the head office; no delay in reporting, false reporting or concealment for any reason. In the process of emergency response, the situation should be renewed in a timely manner.

3.2 Advance Disposal

After the occurrence of employee casualty accidents, the accident unit should immediately start the emergency response plan, timely and effective advance disposal, control the situation, and prevent the accident from escalating and expanding the consequences.

3.3 Emergency Response

3.3.1 After receiving the information report of personal injury and death accident, the leading group of the head office of the emergency response issued the order to start the emergency plan.

3.3.2 After receiving the information report of personal injury and death, the leading group of the head office emergency response team, together with the relevant professionals, should immediately go to the scene, participate in the command and rescue of the accident and the accident investigation and treatment, and report the accident investigation and treatment report on time.

3.3.3 According to the accident rescue needs to mobilize rescue teams and equipment, equipment and so on.

3.4 The end of the emergency

After the accident, in line with the principle of "who started, who is responsible for", the leading group of emergency response at all levels to declare the end of the emergency.

4 rescue and medical

4.1 After the accident on-site personnel should be quickly sent to the hospital for treatment of the injured, the conditions of the region to call the local emergency center (number: area code + 120), requesting assistance;

4.2 In order to avoid aggravation of injuries deterioration of injured personnel, before they are not sent to the hospital should be Take appropriate treatment measures;

4.3 Non-life-threatening injuries sent to designated hospitals for treatment;

4.4 Life-threatening injuries sent to the nearest hospital, so that the injured get timely and effective treatment, to be out of danger and then transferred to designated hospitals for treatment;

4.5 To promptly notify the families of the injured, and to do a good job of pacifying the injured and their families.

5 training and exercises

5.1 In accordance with the principle of hierarchical management, the organization of pre-service training of rescue personnel, regular professional training in rescue knowledge, and constantly improve the rescue skills;

5.2 Emergency response teams at all levels should be organized annually to carry out an exercise of the plan, and constantly summarize the improvement of emergency response and disposal of real combat ability.

6 plan management

6.1 each company should be based on the plan to develop their own implementation details, reported to the head office for approval.

6.2 Emergency plan formulated, in principle, regularly revised, in case of special circumstances can be revised at any time. After the revision of this plan, reported to the relevant departments for the record and copied to the relevant departments and units.

6.3 This plan is responsible for the interpretation of the head office.

6.4 This plan shall be implemented from the date of issuance.

Emergency plan for casualty accidents4

I. Organization

Emergency response commander-in-chief: manager

Emergency response deputy commander-in-chief: deputy manager

Members: safety officer, treasurer, loading and unloading captains, loading and unloading shift supervisors, salesmen

Emergency response command is located in the office of the coalfield:

Second, the duties of the emergency rescue headquarters:

(1), the organization of the development and approval of the accident emergency rescue plan;

(2), the establishment of a sound emergency rescue team, the organization of the team training exercises;

(3), to ensure that the emergency funds required and the configuration of the necessary materials and equipment;

p> (4), the decision to issue and release the emergency rescue signal, organization and command of emergency rescue teams and emergency rescue operations, if necessary, to make the decision to request assistance from the relevant parties.

(5), inform the higher authorities of the situation;

(6), summarize the lessons of the accident.

Third, the accident scene of the emergency measures

Deputy commanders in the early stages of personal injury and death accidents, the company's emergency response plan before the start, you need to complete the report, the implementation of emergency care, maintenance of the accident scene, to maintain the normal operation of the work, it is the follow-up of the rescue work of the smooth progress of the role of the pivotal role of the following specific tasks Aspects:

(1) after the occurrence of personal injury and death accidents, by the safety officer designated to maintain the order of the accident scene, to prevent unrelated personnel from entering the accident scene, to prevent secondary injuries, and at the same time to report to the general director of the emergency treatment.

(2) The deputy commander should assign someone to guide the relevant personnel to enter the accident scene.

(3) The deputy commander, according to the actual situation at the accident scene, utilizes the on-site resources and takes reliable measures to prevent the accident from expanding, such as: fire fighting can activate the "Fire Extinguishing and Emergency Evacuation Plan"; electrocution accidents can activate the "Electrocution Accident Emergency Handling Plan". And designate experienced personnel to rescue the injured personnel after taking effective safety measures.

(4) the accident scene personnel should be based on their own practical skills, the implementation of on-site rescue of injured people, such as: cardiopulmonary resuscitation (artificial oxygenation), trauma bandages, etc., while the nearest formal hospitals should be quickly contacted to carry out professional ambulance.

Four, the relevant departments of the emergency measures

For the special nature of personal injury and death accidents, that is, human life is hurt, the following relevant departments should take measures quickly:

(1) duty cadres in the shortest possible time after the receipt of the report should be rushed to the scene of the accident to carry out treatment at the same time immediately to the company's general director of the emergency management Report, and should contact the local 120 emergency center, requesting support.

(2) safety officers and operators in the report, should quickly enter, blockade the accident scene, to maintain the accident scene security, and comprehensive collection of accident information, to guide the rescue work of foreign rescue workers, to assist the medical staff to rescue the injured.

Fifth, the implementation of the emergency treatment of personal injury and death

Emergency response command in the receipt of the report of personal injury and death, according to the actual situation of personal injury and death accidents should be started in due course of the emergency response plan, the groups in the notification, into the emergency state. According to the categories of personal injury and death accidents, the following handling procedures are implemented.

(1) The on-site command group, according to the actual situation at the scene, maintains normal dressing operations, while setting up isolation at the accident site as needed, and assigns personnel to the scene to conduct inspections, and take measures to control the state of the causative agent, the causative agent as soon as possible, and restore it to a harmless state under the premise of trying to protect the scene of the accident to be investigated.

(2) The safety officer should block the accident scene, maintain the security of the accident scene, and comprehensively collect accident information.

(3) The medical rescue team should take appropriate rescue measures according to the injury of the personnel, and should correctly guide the transfer of injured personnel; the rescuers should also do a good job of self-protection in the process of rescuing the injured.

(4) other professional groups according to the actual needs of the on-site command group, timely assistance.

(5) After the accident, the aftercare team should do a good job of receiving the families of injured people, appeasement and insurance claims.

Sixth, fill out the "accident handling rectification book" in a timely manner, and reported to the relevant departments.

Casualty Accident Emergency Plan 5

1 General

1.1 Electrocution is a common accident in the production and operation process of power generation enterprises, and it is also the main type of personal injury and death in enterprises. In order to timely and effective response to electrocution accidents, do our best to rescue the electrocution injured from the death line, the accident on the casualties to a minimum, according to the "power generation enterprise personal injury and death of the General Emergency Response Plan", the development of the "xxxx Ltd. electrocution personal injury and death of the emergency response plan".

1.2 This plan is formulated in accordance with the policy of "Safety First, Prevention First, Comprehensive Management" and the principle of "Protecting People, Protecting Power Grid, Protecting Steam Supply and Protecting Equipment", and in conjunction with the actual situation.

1.3 This emergency plan applies to all units of xxxx Co., Ltd. engaged in production, operation of the employees and in the area of the enterprise engaged in various types of production, operation of foreign personnel.

2 types of accidents, hazard analysis and basic principles of emergency response

2.1 Types of electrocution accidents and the law

Most of the electrocution accidents occur due to the person directly touched by the electrically charged body or contact with insulation damage and leakage of the equipment, standing in the vicinity of the grounding fault point may also occur in the event of personnel electrocution. The accident can also happen when people stand around the ground fault point. Electrocution can be divided into the following categories:

(1) people directly in contact with the charged body of the electrocution: according to the human body touched the charged body and the way the current through the human body, such accidents can be divided into single-phase electrocution and two-phase electrocution. Single-phase electrocution refers to the human body on the ground or other grounded conductors, a part of the human body touches a phase of the electrified body and the accident occurred. Two-phase electrocution refers to the human body in two places at the same time touching the two charged body and the occurrence of the accident, the risk is greater. Such accidents account for more than 40% of all electrocution accidents.

(2) and insulation damage to electrical equipment contact electrocution: under normal circumstances, the metal casing of electrical equipment is not charged, when the insulation is damaged and leakage, touching these shells, electrocution will occur, electrocution and contact with the same charged body. Such accidents account for more than 50% of all electrocution accidents.

(3) step voltage electrocution: when the charged body grounded current into the ground, the current in the grounding point around the voltage drop, people in the grounding point around the voltage drop between the two feet, that is, resulting in step voltage electrocution.

2.2 Analysis of the causes of electrocution

(1) did not strictly implement the work ticket system. Such as: overhaul does not use the work ticket; not experienced power and work on both ends of the lot is not hung on the grounding wire that is working on high-voltage equipment; unsupervised, a single person working on high-voltage equipment, not hanging signs and installing cover rails; insufficient knowledge of electrical safety, unskilled technology, without the examination of short-term labor contracts, temporary workers and other non-electricity staff working on high-voltage equipment;

(2) did not Strictly implement the operation ticket system. For example: not using the operation ticket for the reverse gate operation; unsupervised electrical reverse gate operation and protection of the throwback operation; blindly carrying out the electrical reverse gate and protection of the throwback operation without the "three checks"; blindly carrying out the electrical reverse gate operation without the singing of the ticket and the recitation; and not using the qualified safety tools for the operation in accordance with the regulations;

(3) Portable and mobile equipment management is not standardized, improper use and so on.

2.3 Hazard Analysis of Electric Shock Accidents

The human body due to the passage of electric current can be divided into two types of injuries suffered by the electrical injury and electric shock, and its harm to the human body is as follows:

(1) electrical injury electrical injuries are due to electric shock to the human body's appearance of localized injuries, burns and electric branding and so on. This kind of electrocution is often caused by the occurrence of electric sparks or arcs, which can cause a stinging sensation.

(2) electric shock electric shock is an electric shock casualty. When the human body and the electric conductor contact, there is a current through the body, the current generated by the heat of the human epidermal burns, blisters, so that the skin resistance suddenly reduced, the current increased; in the large current through the human body, the nerve cells are injured, resulting in local paralysis, so that electrocution can not be self-evacuated from the situation, by the electric "sucked"; the current on the human body to further aggravate the injury to a part of the human body, to make a part of the electric current, the electric current, the electric current, the electric current and the electric current. The current on the human body to further aggravate the injury, so that part of the current through the heart, causing paralysis of the heart or respiratory organs, resulting in fatal accidents.

2.4 basic principles of emergency treatment of electrocution accident

First aid for electrocution must be a matter of minutes and seconds, immediately on the spot, quickly with CPR first aid, and constantly adhere to carry out, at the same time as early as possible with the local medical department to contact the local medical personnel for medical personnel to quickly and urgently rushed to the place where it happened to take over the work of rescue, in the medical personnel did not take over the work of rescue, on-site rescue personnel should not give up the scene of rescue, not to mention only the rescue, but also the medical staff, the medical staff should not give up the scene of rescue. Rescue, not to mention the absence of respiration or pulse stopping according to unauthorized judgment of the casualty death, give up rescue.

3 electrocution emergency rescue leading group and emergency rescue command organization and its responsibilities

3.1 electrocution emergency rescue leading group and emergency rescue command organization

Leader/commander-in-chief: manager

Deputy leader/commander-in-chief: deputy manager

Members: electric control department, Workshops, offices in charge of

The daily management office of this emergency plan is located in the company's safety and environmental protection department, the minister and director of the daily management office.

3.2 Electrocution Emergency Response Leading Group Responsibilities

(1) Organize the preparation and approval of the emergency response plan for electrocution accidents, formulate the emergency drill plan, and organize the implementation and review to ensure the effectiveness of the emergency response plan, compliance.

(2) is responsible for emergency response plan document maintenance, updating, reporting management.

(3) electrocution incident occurred, responsible for first aid command and scheduling, implementation of logistics, to assist in accident handling and investigation.

(4) develop training programs to make the relevant personnel clear emergency preparedness and response requirements and their responsibilities.

(5) the development of drill plans, regular organization of emergency drills, and after the drill, evaluation of the effectiveness of the drill, put forward the views of improvement.

3.3 Emergency rescue command organization responsibilities

3.3.1 In the event of electrocution accident, the commander-in-chief or the commander-in-chief entrusted the deputy commander-in-chief rushed to the scene of the accident to carry out on-site command, set up an on-site command department, approve the on-site rescue program, and organize on-site salvage.

3.3.2 According to the accident immediately in accordance with the procedures set out in this plan, the organization of forces on the scene to deal with the accident, and timely report to the leadership of the company, if necessary, to report to the local government.

3.3.3 Responsible for reporting the accident and the progress of treatment to the company leaders at each level.

3.3.4 Emergency state elimination, declare the end of emergency operations.

4 prevention of electrocution accidents

4.1 Regularly organize the study of the "Electrical Safety Regulations", to improve the awareness of electricity safety, pay attention to the hazards brought about by electrocution accidents, and to prevent the occurrence of electrocution accidents.

4.2 Raise awareness of the importance of the implementation of the "two votes", and strictly implement the "two votes" system to prevent the occurrence of electric shock accidents.

4.3 In accordance with the requirements of the Electrical Safety Code, take strict safety and technical measures to strengthen the maintenance of electrical facilities to prevent accidental electrocution caused by the aging of the equipment; strengthen the management of safety instruments to prevent accidental electrocution caused by unqualified instruments.

Relevant safety technical measures include:

(1) safety technical measures regarding electrical insulation, screen protection and safety spacing;

(2) protective earthing and protective zeroing measures to prevent indirect electrocution;

(3) according to the characteristics of the production and workplace, the use of the appropriate level of safety voltage;

(4) power consumption Equipment configured with the necessary leakage protection devices;

(5) Reasonable use of basic safety and protective equipment, such as insulating rods, insulating pliers, high-voltage tester pens, etc., and reasonable use of auxiliary safety and protective equipment, such as insulated gloves, insulated (boots) shoes, rubber mats, insulated table, etc..

4.4 In accordance with the requirements of the "safety regulations", develop and implement the organizational measures for the safety of electricity, develop a plan of measures for the safety of electricity, and conscientiously implement the rules and regulations

4.5 Strengthen the staff of the prevention of electrocution skills training and electrocution emergency rescue knowledge training.

5 Information Reporting Procedures

5 Immediate Reporting and Accident Reporting

After the occurrence of electrocution accidents, the scene of the accident should be immediately reported to the competent department, the Department of Safety and Environmental Protection, the competent department, the Department of Safety and Environmental Protection to the deputy general manager in charge of the report, and promptly reported to the leadership of the group company level by level;

Accidental units shall be Within one hour, the cause of the accident, processing, casualties, rescue situation in the form of express report to report to the leadership of the group company level by level.

6 Emergency Disposal

6.1 Emergency plan start

6.1.1 In the event of an electrocution accident, the operator at the scene of the accident shall promptly report the scene situation to the competent leader, who shall promptly report to the leader of the leading group of the main, deputy leader, and at the same time notify the situation to the Department of Safety and Environmental Protection. Accident scene operators can also report directly to the leading group of positive and negative leader, while reporting to the Ministry of Safety and Environmental Protection.

6.1.2 After receiving the report, the head and deputy head of the leading group, according to the specific circumstances, to determine whether to start the plan.

6.2 Critical Incident Response

6.2.1 Upon receipt of the report from the relevant personnel at the scene of the accident, all the members of the leading group of the emergency command organization at the scene (including the team leader, deputy team leader and members) must immediately go to the scene of the accident to organize rescue, protect the scene, and take active measures to protect the lives of the injured, alleviate the injuries, and reduce the pain, and at the same time, according to the need of the injuries, quickly Contact the medical department for treatment.

6.2.2 found someone electrocuted, should immediately disconnect the power supply, so that the electrocuted person quickly from the power supply. If the injured person is confused, judging the consciousness of no, breathing and heartbeat weak, in the absence of moving, no rush to deal with trauma, immediately mouth-to-mouth artificial respiration first aid, and according to the condition of the injury quickly contact the medical department for treatment. Found that the electrocuted person breathing, heart stop, should be immediately at the scene on the spot rescue, with cardiopulmonary resuscitation to support the respiratory cycle, the brain, heart vital organs oxygen supply, in the medical personnel to arrive before the delay or interruption.

6.2.3 Before the electrocuted person is disconnected from the power source, the rescuer shall not touch the injured person directly with his hands.

6.2.4 If the electrocuted person is in a high place, reliable measures shall be taken to prevent the electrocuted person from falling from a high place after he/she is freed from the power source.

6.2.5 When electrocution occurs at a high place, in order to make the rescue more effective, the injured person should be brought to the ground in a timely manner. After completing the above measures, the casualty should be immediately and rapidly sent to the ground with a rope, or take possible rapid and effective measures to send to the platform.

6.2.6 After the accident, the highest person in charge of the scene is the highest commanding officer of the scene, and the command and dispatch is unified. The highest commanding officer should keep a cool head and command the on-site rescue work in an orderly manner, to ensure that the injured are given timely and effective rescue.

6.2.7 On-site personnel involved in rescue work, should actively participate in emergency rescue work, obey the command and scheduling of the commanding officer, rescue experience should be rushed to the scene of the accident in a timely manner, to participate in the rescue of the injured, and other personnel should maintain the order of the scene, cooperate with the work of the rescue personnel.

6.2.8 such as the casualty's heartbeat and respiration have been restored after resuscitation, can be suspended CPR operation, but the heartbeat and respiration recovery in the early stage of the possibility of another arrest, should be closely monitored, can not be paralyzed, and should be ready to resuscitate again. After the initial recovery, the casualty may be confused or trance, agitation, should try to make the casualty quiet.

7 emergency supplies and equipment security

7.1 The scene can be prepared with some rescue drugs such as adrenaline and other drugs.

7.2 On-site electrocution rescue, the use of drugs such as epinephrine should be cautious attitude. If there is no necessary diagnostic equipment and conditions and enough certainty, shall not be used indiscriminately. Rescue electrocution in the hospital, by the medical staff by medical equipment diagnosis, according to the diagnostic results and then decide whether to use.

8 post-disposal

The site operators should cooperate with the medical personnel to do a good job of emergency rescue of injured people, the Department of Safety and Environmental Protection should do a good job of protecting the scene, taking pictures, accident investigation and other aftermath work. Accident investigation and treatment in accordance with the National Electric Power Company "accident investigation procedures".